No. SX-DSV02829 -
6-
Item
Description
C
o
m
mo
n
Auto-tuning
Identifies the load inertia real-time and automatically sets up the gain that meets the stiffness
setting when the motor is running with upper and internal operation commands.
Protective function
Overvoltage, undervoltage, overspeed, overload, overheat, overcurrent, positional
overdeviaition, EEPROM failure, etc.
Alarm data trace back
Tracing back of alarm data is available
Overload protection curve select function
Available
Overload warning threshold Setting function
Available
Maximum PDO data length *1)
46byte(RxPDO
:
21byte TxPDO
:
25byte)
Touch Probe Function *2)
Position latch function : Available number is 1.
Adaptive filter
Cycle time(Communication cycle)
Available number
250μs
0(Not available)
500μs
1
1000μs
2000μs
4000μs
Notch filter
Cycle time(Communication cycle)
Available number
250μs
3
500μs
1000μs
4
2000μs
4000μs
*1) For information on the maximum PDO data length, refer to the section 3-7 in the Technical Reference EtherCAT
Communication Specification (SX-DSV02827).
*2) For information on the touch probe, refer to the section 6-9-1 in the Technical Reference EtherCAT Communication
Specification (SX-DSV02827).
R1.00
Motor Business Unit, Panasonic Corporation