No. SX-DSV02829 -
68-
4-7-4 Automatic linear motor setting with tool
The initial parameter (current gain, feedback scale direction, CS direction) for the combination with a linear motor can be
automatically set by using the automatic setting tool (MotorAutoSetup).
Parameter changed by the automatic linear motor setting
The automatic linear motor setting updates the parameters below:
Class No.
At-
trib-
ute
*1)
Title
Range
Unit
Function
3
26
R
Feedback scale &
CS reversal
0-3
-
Set the reversal of the feedback counter and CS signal direction of the
feedback scale.
[Scale]
[CS signal]
0: not reversed
not reversed
1: reversed
not reversed
2: not reversed
reversed
3: reversed
reversed
The logic setting of CS signal is valid only when the CS signal is selected
(Pr9.20 = 1).
9
13
B
Proportional
current gain
0-32767
-
Set a proportional current gain.
9
14
B
Integral current
gain
0-32767
-
Set an integral current gain.
9
21
R
CS phase
0–360
Electric
angle
(°)
Set the relative phase between the motor's induced voltage and CS signal.
This setting is valid only when CS signal is selected (Pr9.20 = 1).
*1) For information on the parameter attribute, refer to the section 9-1.
▪ To set Pr9.13 “Proportional current gain” and Pr9.14 “Integral current gain” by using the automatic linear motor
setting, set Pr9.12 “Automatic current response adjustment” to zero.