No. SX-DSV02829 -
189-
Class 9: Linear-related
Class
No.
Title
Unit
Range
Size
[byte]
Function / Contents
Attribute
Related
control
mode
Reference
9
00
Motor type
selection
―
0–2
2
Select the type of a motor that will be
connected.
R
All
4-7-1-1
4-7-1-2
4-7-4
01
Feedback scale
resolution/
Number of scale
pulses per rotation
0.001
μm
/pulse
0–
16777216
4
[Motor type: Linear]
Set up the resolution for the feedback
scale.
R
All
4-7-1-1
4-7-1-2
4-7-4
[Motor type: Rotary]
Set the number of pulses of the feedback
scale per revolution.
02
Magnet pole pitch
0.01mm
0–32767
2
[Motor type: Linear]
Set up the magnet pole pitch.
* For the rotary type, no settings are
required.
R
All
4-7-1-1
4-7-4
03
Pole logarithm per
rotation
Pole
logarithm
0–255
2
[Motor type: Rotary]
Set up the pole logarithm per motor
rotation for the motor.
* For the linear type, no settings are
required.
R
All
4-7-1-2
04
Mass of motor's
movable section/
Motor inertia
0.01kg
/0.00001
kgm^2
0–32767
2
[Motor type: Linear]
Set up the moving portion’s mass of
motor.
R
All
4-7-1-1
4-7-1-2
4-7-4
[Motor type: Rotary]
Set up the motor inertia.
05
Rated motor
thrust/rated motor
torque
0.1N
/0.1Nm
0–32767
2
[Motor type: Linear]
Set up the rated thrust for the motor.
R
All
4-7-1-1
4-7-1-2
4-7-4
[Motor type: Rotary]
Set up the rated torque for the motor.
06
Rated effective
motor current
0.1
Arms
0–32767
2
Set up the rated effective current for the
motor.
R
All
4-7-1-1
4-7-1-2
4-7-4
07
Maximum
instantaneous
motor current
0.1A
0–32767
2
Set up the maximum instantaneous current
for the motor.
R
All
4-7-1-1
4-7-1-2
4-7-4
08
Motor phase
inductance
0.01mH
0–32767
2
Set up the phase inductance for the motor.
R
All
4-7-1-1
4-7-1-2
09
Motor phase
resistance
0.01Ω
0–32767
2
Set up the phase resistance for the motor.
R
All
4-7-1-1
4-7-1-2
10
Maximum
over-speed level
(mm/s)
/(r/min)
0–20000
2
Set up the maximum over-speed for the
motor.
R
All
4-7-1-1
4-7-1-2
4-7-4
11
Carrier frequency
selection
―
0–1
2
Select the carrier frequency.
0: 6 kHz
1: 12 kHz
R
All
4-7-1-1
4-7-1-2
12
Automatic current
response
adjustment
%
0–100
2
Set up the criteria for current response for
the automatic setup of Pr 9.13
“Proportional current gain” and Pr 9.14
“Integral current gain”.
R
All
4-7-2
13
Proportional
current gain
―
0–32767
2
Set up the proportional current gain.
R
All
4-7-2
14
Integral current
gain
―
0–32767
2
Set up the integral current gain.
R
All
4-7-2
17
For manufacturer's
use
-
-
2
Permanently set at 0.
-
-
-
18
For manufacturer's
use
-
-
2
Permanently set at 0.
-
-
-
19
For manufacturer's
use
-
-
2
Permanently set at 0.
-
-
-
R1.00