210
⿎
Arc
1
3
4
2
Description
1
Start Point X/Y :
End Point X/Y :
Specifies the starting / ending point of arc.
Setting Range
-45.000 to +45.000 mm
(LP-V10)
-55.000 to +55.000 mm
(LP-430 / LP-420 / LP-410)
-80.000 to +80.000 mm
(LP-435 / LP-425 / LP-V15)
-27.500 to +27.500 mm
(LP-431 / LP-421 / LP-411 / LP-W052)
2
Radius:
Inputs the radius of arc.
Setting Range
0.010 to 300.000 mm
3
Direction:
For the arc in counterclockwise direction, select [CCW] and in clockwise direction, select [CW].
4
Open Ang. (Open Angle):
Select the open angle of the arc from “under” or “over” 180 degree.
Open Angle
Counterclockwise
Clockwise
Open Angle
Start Point
(X,Y)
End Point
(X,Y)
Radius
Radius
Radius
Radius
Open Angle
Counterclockwise
Clockwise
Open Angle
Start Point
(X,Y)
End Point
(X,Y)
Radius
Radius
Radius
Radius
•
Open Angle: under 180 degree
•
Open Angle: 180 degree or more
ME-LP400V-OP-6
Содержание LP-V Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...