263
⿎
Ethernet
This screen specifies the Ethernet communication setting. Set this to perform Ethernet communication.
Select the [Ethernet] and press [SETUP] button to show the Network Setting Screen.
Press [OK] to save the settings. (Press [Cancel] to discard the changes.)
6
1
2
3
4
5
Environment 3 Screen
Network Setting Screen
Item
Description
1
IP Address
: Sets the IP address.
Setting Range
1.0.0.0 to 223.255.255.255 (except 127 in the 1st octet)
Initial setting
192.168.1.5
2
Subnet Mask
: Sets the subnet mask.
Setting Range
128.0.0.0 to 255.255.255.254
Initial setting
255.255.255.0
3
Default Gateway
: Sets the default gateway.
Setting Range
1.0.0.0 to 223.255.255.255(except 127 in the 1st octet)
Initial setting
None (blank)
4
Port
: Sets the port.
Setting Range
5001 to 65534 [except 9090 and 9091]
Initial setting
9094
5
MAC Address
: Displays currently set MAC Address.
6
BCS Command GS
→ FNC1
: This setting is available only when the barcode “GS1 DataMatrix” is used. To set the
barcode character by using serial communication command “BCS”, select either “GS”
(OFF) or “FNC1” (ON) as the separator of AI data with the variable length.
Setting Range
ON: the separator of variable length AI data is “FNC1”.
OFF: the separator of variable length AI data is “GS”.
Notice
•
The communication control of the laser marker through the Ethernet should be performed in a secure network
environment.
Reference
• “Octet” is a 3-figure value delimited by dots. From the beginning, it is called the “1st octet”, “2nd octet”, and so forth.
•
Depending on the combination, there are cases where IP Address and Subnet Mask values cannot be set even if they
are within the setting range.
•
Make sure that the IP address for the laser marker on the network is not overlapping the IP address for the PC.
•
When the backup data is restored to the laser marker, communication parameter settings are overwritten with the
backup data. After restoring, confirm the IP address and other parameters.
ME-LP400V-OP-6
Содержание LP-V Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...