302
ERROR
CODE
Error details
Measures
E230
to
E233
Laser error.
•
Temperature in the laser oscillator exceeds the
limit.
•
Instantaneous interruption of laser power supply is
detected.
•
Head control cable is not connected properly.
•
Fiber cable is broken. (only for LP-V/LP-W series)
•
Failure of laser oscillator is detected.
•
There might be occurred the malfunction of the
internal shutter.
Turn the key switch to the OFF position and check the
followings: Cool the laser oscillator thoroughly before
restarting the controller.
•
Check that the ambient temperature is in the
specified operating temperature.
• Check the air filter, the air intake / exhaust port
and the fan of the cooling part for clogging.
•
Check and correct the power status.
•
Check if the AC power line is effected by noise.
•
Connect head control cable and head power cable
properly, and restart with key switch.
• When not recovered, contact our sales office.
E235
*2
There is a short line segment that cannot be marked.
Check and delete if there is an unnecessary short
line segment in logo files.
Set scan speed smaller, or “0” to “Pre-Scan time” on
Laser Setting.
E240
E241
The temperature of the laser has reached its limit.
•
Check that the ambient temperature is in the
specified operating temperature.
•
Make sure cooling fan operates.
• When not recovered, contact our sales office.
E250
Detected a decrease in power supply voltage.
•
Check and correct the power status.
•
Check if the AC power line is effected by noise.
•
Connect head power cable properly, and restart
with key switch.
• When not recovered, contact our sales office.
E300
A head is not connected. Shut off a power and
connect a head.
Connect head control cable properly, and restart with
key switch.
E310
Unsupported head.
Change either head or controller.
•
Connect head control cable properly, and restart
with key switch.
•
Check if head with correct model has been
connected. If it is wrong, replace head or controller
with correct one.
E311
System error.
•
Head control cable is not connected properly.
•
Wrong head has been connected to controller.
E312
System error.
Restart the laser marker. When not recovered,
contact to our sales office.
*2 : Error that may occur for LP-400 series only.
ME-LP400V-OP-6
Содержание LP-V Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...