213
Description
6
Radiation Time :
Specifies the laser radiation time.
Setting Range
0.1 to 99999.9 ms
7
Laser Power Correction :
Correction of each radiation point for the laser power set at laser setting.
If the correction rate is set to 0%, the marking image is displayed in gray and marking is not executed.
Setting Range
0 to 200%
8
INPUT :
Pressing INPUT button establishes the specified radiation position and time.
9
DELETE :
Pressing DELETE button deletes the selected radiation position and time.
10 ALL DEL :
Pressing ALL DEL button deletes all radiation position and time in the table.
11 List of Point Radiation Conditions :
Displays the setting condition radiation position and time. Up to 50 radiation points can be set in one condition list.
WARNING
•
Since the arbitrary point radiation function carries on radiating the laser onto
the one point, it will provide high energy density.
It may flame up or burn depending on the material to be used for processing or
processing condition.
ME-LP400V-OP-6
Содержание LP-V Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...