218
Description
4
Jump (Jump adjustment) :
Adjusts the waiting time for starting radiation at the start point of the line.
It is applied only to the lines which distance to the next line is long.
Setting a large value improves the disordered lines at the start points.
Setting a larger value makes the marking time longer.
Setting Range
0 to 100
Initial Value
0
5
Pre-scan Time :
The pre-scan time adjusts the start-up and fall times of the laser beam at the start/end points. Setting the scanning
period improves the too thick marking at the start/end points.
Setting larger value makes the marking time longer.
Setting Range
0.00 to 10.00 ms
Initial Value
0.00 ms
6
Point Rad. On/Off (Point Radiation ON/OFF Adjustment) :
Adjusts the on/off timing of the radiation for “4-10-6 Point Radiation Condition” (P.212).
On time specifies the waiting time for starting radiation.
Off time specifies the waiting time for moving to the next radiation points.
Setting a larger value makes the marking time longer.
Setting Range
0.00 to 9.99 ms
Initial Value
0.00 ms
7
Laser Frequency (LP-400 series only) :
Selects the frequency of laser from 5, 10 or 20 kHz. Setting a small value is likely to make the line dotted at the
high-speed scanning.
Setting Range
5kHz, 10kHz, 20kHz
Initial Value
20kHz
ME-LP400V-OP-6
Содержание LP-V Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...