167
ERROR
CODE
Error description
Measures
E680
The marking time cannot be measured with Marking to
Flying Object set in combination with 3D marking.
• Set the moving direction to “still” in the trigger
setting.
• Select 2D setting with overall (general)
condition.
E681
Displacement sensor error signal was detected.
When not using the displacement sensor:
Connect the attached displacement sensor
input connector to the back of the controller.
The connector must be connected even when
the displacement sensor is not being used.
When using the displacement sensor:
• Confirm the displacement sensor and
measurement status and eliminate the cause
of the error.
• Confirm the displacement sensor specifications
and adjust to output the correct error signal.
• Check the displacement sensor power supply.
• Check the displacement sensor error signal
terminal wiring.
• If the error signal is not used, short circuit the
displacement sensor input connectors 1 and 2.
E690
Cannot finish measurement during specified time.
• Reduce marking contents and measure
marking time.
• Speed up scan speed.
E700
Unable to lase as laser pumping is turned OFF.
Turn ON the laser pumping and after the laser
pumping has completed, start marking.
E701
Started laser power check in laser pumping OFF state.
Turn ON the laser pumping and after the laser
pumping has completed, start power check.
E710
Marking energy error.
Check the thresholds (upper and lower limit) of
the marking energy.
E800
Trigger input occurred while marking ready output is set
to off.
• Change marking timing so that trigger input is
performed after marking ready output is turned
on.
• Check wiring and control procedure for input
terminal, wiring to communication port, and the
procedure of the communication command.
E811
Laser Stop 1 of the input terminal is opened.
• Check the wiring of the laser stop 1 input
terminal and contact of the switch.
• Confirm operation logic of connection device.
E900
Existed invalid functional character for simultaneous use.
The following combination of the functions are not
available in one file.
• Serial data marking function and rank function
• Serial data marking function and external offset
function by I/O
Delete any one of these functions from the file.
E901
Existed invalid character for converting into 2D code.
Set the character that can be converted into 2D
code.
ME-LPS-SSM-8
Содержание LP-S Series
Страница 15: ...15 MEMO ME LPS SSM 8 ...
Страница 26: ...26 Chapter 1 Specification ME LPS SSM 8 ...
Страница 41: ...41 Chapter 2 Preparation ME LPS SSM 8 ...
Страница 78: ...Chapter 3 Connection for External Control ME LPS SSM 8 ...
Страница 126: ...Chapter 4 Maintenance ME LPS SSM 8 ...
Страница 148: ...Troubleshooting ME LPS SSM 8 ...
Страница 169: ...Index ME LPS SSM 8 ...
Страница 172: ...172 MEMO No 9000 0066 16V ME LPS SSM 8 ...
Страница 173: ...No 9000 0066 16V ...