138
6.
After setting the laser power meter, press [NEXT].
7.
Press [LASER CHECK].
Press [START] to radiate the laser and measure the output power with
the laser power meter.
Laser radiation is terminated by pressing [STOP].
WARNING
• Be sure to wear protective goggles.
• During the radiation, the laser energy is concentrated to one point. Use due
caution with long period radiation, it may cause a fire or damage to the object.
8.
Confirm if the measurement results are within the following range.
Laser marker model name
Optimum value of the measurement results
LP-S502, LP-S500, LP-S505
32.6W to 34.6W
LP-S202, LP-S200, LP-S205
13.2W to 14.0W
* “Laser Check” in this function outputs the laser power corresponding to 80% of the full power.
If the measurement results are within the optimum value, “Power Correct” described from the next procedure is not
necessary and press [CANCEL] to close the window.
If the measurement results are out of the optimum value, adjust the power correction rate.
ME-LPS-SSM-8