Page 1-66
Check Every 560 Hours (Every Month)
1-5-6
Lubricating the X-Y Unit and Head Unit (Rear Side)
Lubricate to the linear bearing and ball screw of each axis of X-Y unit and Z- axis ball screw of
each A, B, and C transfer head through the grease nipple.
1.
Turn on the servo switch.
2.
Press
UNLOCK
and UX, UY .
• The X-Y unit moves to the origin position.
3.
Turn off the servo switch.
OFF ( ) ON ( )
SERVO
OFF ( ) ON ( )
SERVO
Front side
493C-E-MMA01-A08-01
1
2
4
3
C B A
433C-090E