48
Chapter 3
3.2 Upper and Lower Limit Value Settings
Set the upper and lower limit values for the judgment of the measured value.
Judgment is made as to the comparison between the value after display
scaling and the upper and lower limit settings. Before entering the upper limit
value, determine the display scale.
If holding measurement is selected, judgment is made as to the held value.
In the calculation mode, the result of calculation is judged.
3.2.1 Setting the Upper and Lower Limit Value Entry Method
There are the following two methods for entering the upper and lower limit
values used for judgment of the detected value.
POINT
Press in the
upper/lower limit value
setting mode.
Value entry setting
Detection displacement
setting (teaching)
Mode
Description of action
Operation
Press and hold in
the upper/lower limit
value setting mode.
The upper or lower limit value can be
entered directly as a digital value.
The detection displacement value is set
directly as an upper or lower limit value.
The object to be detected (workpiece)
can be used to enter the setting.