74
Chapter 4
4.3.3 Output Delay
Select the off-delay timer setting from the options shown in the table below.
Off-delay timer
The timing for switching the judgment output from ON to OFF retreats with
the timer setting.
The timing chart is shown below.
[Timer type and change in GO output (in the case of "to" timer setting)]
POINT
・
The delay becomes longer with the interference prevention setting.
Actually operate to check. For details, refer to Section "
4.7 Interference
prevention Setting
" on page 90.
・
If the number of connected units is as large as eight, the delay is 12.8
times (19.2 times with
GP-X22KL
) that of a single unit.
No delay
100ms
200ms
400ms
800ms
1,000ms
Hold
Indication in lower line
Description of action
100ms off-delay
No delay
200ms off-delay
400ms off-delay
800ms off-delay
1,000ms off-delay
Delay
Judgment output is held until the reset
signal is issued.
Off-delay timer
Regular output
(without timer)
t
o
ON
OFF
ON
OFF