17
Chapter 1
1.6.2 Mounting the Sensor Head
Tighten the sensor head to the torque specified below.
Mounting with set screw
Use an M3, or less, cup-point set screw.
<Column type>
Mounting with nut
<Screw type>
Distance from surrounding metal
As metal around the sensor may affect the detection, take care of the fol-
lowing.
<Embedding of the sensor in metal>
Measurement value or analogue voltage output may be changed if the
sensor is completely embedded in metal. Keep the minimum distance
specified in the table below.
A
Set screw (M3 or smaller)
(Cup point)
D
C
Metal
GP-X3S
GP-X5S
GP-X8S
GP-X10M
GP-X12ML
GP-X22KL
10
18
14
3
14
20
50
50
Model
D(mm)
C(mm)
GP-X3S
GP-X5S
GP-X8S
0.1N
・
m or less
0.58N
・
m or less
0.44N
・
m or less
Model
4 to 16
Tightening torque
A(mm)
Note: Avoid tightening excessively.
5 to 16
Notes : 1)
2)
In case of without a nut. If a nut is fitted,
this value will be 23.5mm or more.
Mount such that the nuts do not protrude
from the thread portion.
GP-X10M
GP-X12ML
9.8N
・
m or less
20N
・
m or less
Model
7 or more
14 or more
GP-X22KL
20N
・
m or less
20 or more (Note 1)
Tightening torque
B(mm)
GP-X10M GP-X12ML
Attached
toothed lock
washer
Mounting
plate
B
B
Attached
toothed lock
washer
Mounting
plate
Attached
toothed lock
washer
Mounting
plate
GP-X22KL
B