136
Chapter 7
7.2 What to Do?
When the following phenomenon occurs, check.
P.14
P.88
P.90
P.32
P.88
All indicators do not light up.
The upper and lower lines of the digital
display unit are not lit.
The displayed value does not change.
Check that the cables are connected correctly.
Check that the power saving mode starts without a
trigger in the holding measurement mode.
Check that the controller is in the power saving mode.
Check that the interference prevention function is
validated without an interference prevention cable.
Check that if "Master" or "Slave" of the interference
prevention function is set properly.
In case of the holding measurement mode, is a triger
input ?
S y m p t o m
Reference
page
Confirmation method and remedy
P.63
P.38
P.32
P.38
P.27
P.86
P.74
P.134
P.14
P.9
P.76
P.28
P.81
P.99
All the HI, GO and LO outputs are turned on.
Alarm output does not turn off.
Values are displayed in the upper and
lower lines.
The input signal is not accepted.
The analog voltage output is erroneous.
Hold measurement cannot be performed.
RS-232C communication cannot be
performed.
An erroneous detection distance is
displayed.
Check that "hold" is selected for the output delay
setting.
Refer to the troubleshooting method.
Check that the trigger settings are correct.
Check that timing signals are supplied.
Check that cables are connected correctly.
Check that the input method and input voltage are
free from problems.
Check that analog voltage output scaling is set
correctly.
Isn’t BCD output mode selected?
Check that the hold measurement modes and
trigger conditions are configured correctly.
Check that the displayed setting configures the
upper line for indication of the current value.
Check that the upper and lower lines are
designated in displayed setting.
Check that cables are connected correctly.
Check that communication conditions are
entered correctly.
Check that pin layout of the connector is correct.
Check that the sensor head cable length
selection switch is set correctly.
Check that the display scale is set correctly.
Check that zero setting is performed.
"-----" is displayed.
P.102