Chapter 2
2.2.2 How to Enter a Value
The value entry method for the upper limit is described as an example.
Setting Example
Change upper limit setting 2.0000mm to 4.5000mm.
1.
In the detection state, press the
key.
The MODE indicator (orange) next to the
key lights up to indicate the setting mode, and the
current memory number is displayed.
2.
Press the key.
"
" (H-thr) is displayed.
This is the upper limit setting change menu.
3.
Press the
key.
The most significant digit of the upper limit value
"
" (2.0000) blinks.
4.
Using the
or key, change the blinking
number.
The number increases each time the
key is
pressed.
The number decreases each time the
key is
pressed.
5.
Press the
key to move the blinking digit
and repeat step
4
to change the number.
6.
After changing, press the
key to set the
value.
7.
Press the
key.
The MODE indicator (orange) is not lit to indicate
that the controller has returned to the detection
mode.
*There is another method to replace the upper or lower limit setting with the current de-
tection distance.
*When the least significant digit blinks, press
. All digits blink to indicate positive/
negative conversion.