2.3 Measurement Function
2.3.1 Holding Measurement Function
The holding measurement function includes the following variations.
Normal (no hold):
(nonE)
The measured value is always displayed with analog voltage output and
judgment output.
The displayed value, judgment output and analog voltage output are held
with the timing input.
Reference
For the setting procedure, refer to section "
3.4.2 Manual Mode
" on page 54.
Displayed value
Output value
Measurement
Measured value
Time
Displayed value
0
ON
OFF
Timing input
(External trigger)
Display
Description of action
Normal
Peak hold
Bottom hold
Peak-to-peak hold
Sample hold
Average hold
Name
The measurement result is displayed and
output.
The maximum value at the designated
interval is measured.
The minimum value at the designated
interval is measured.
The difference between the maximum and
minimum values at the designated interval
is measured.
A simple mean of the measurement
interval is measured.
The minimum value at the designated
interval is measured.