50
Chapter 3
3.2.3 Using the Actual Detection Value to Set (Teaching)
Setting example
Change the upper limit value from "1.5000" to "1.7000".
・
Use as the upper threshold (H-thr) value is zero or greater.
・
Enter settings so that the following equation stands true:
Upper limit value (H-thr) - hysteresis width (o-hys) > Lower limit value
(L-thr) + hysteresis width (o-hys).
If the conditions are not satisfied, an error message is displayed.
Press the
key to remove the error indication. Enter the correct value.
POINT
<Detected state>
Upper limit value
setting mode
Set
The blinking value indicates
that the distance between
the sensor head and
detected object is "1.2350".
Change the distance
(blinking value) between
the sensor head and the
detected object to "1.7000"
then press the key to
set.
Press and hold for more than two
seconds to teach.
Press to select "H-thr".