136
Limiters
(continued)
■
Setting the limiters
The limiter positions can be set by following the steps below.
When the position is set, the tally lamp blinks once.
1
Press one of the [CAM1] to [CAM4] buttons to
select the unit.
●
Setting the upper limit position of the movement
range
Press the [
▲
] or [
▼
] button of the wireless remote
control to turn the unit as far as the position which will
serve as the upper limit.
Next, perform the steps in “Basic limiter operations”.
(Press the [MENU] button quickly and then press
the [
▲
] button for 2 seconds while holding down the
[PRESET] button.)
●
Setting the lower limit position of the movement
range
Press the [
▲
] or [
▼
] button of the wireless remote
control to turn the unit as far as the position which will
serve as the lower limit.
Next, perform the steps in “Basic limiter operations”.
(Press the [MENU] button quickly and then press
the [
▼
] button for 2 seconds while holding down the
[PRESET] button.)
●
Setting the left‑most limit position of the
movement range
Press the [
◄
] or [
►
] button of the wireless remote
control to turn the unit as far as the position which will
serve as the left-most limit.
Next, perform the steps in “Basic limiter operations”.
(Press the [MENU] button quickly and then press
the [
◄
] button for 2 seconds while holding down the
[PRESET] button.)
●
Setting the right‑most limit position of the
movement range
Press the [
◄
] or [
►
] button of the wireless remote
control to turn the unit as far as the position which will
serve as the right-most limit.
Next, perform the steps in “Basic limiter operations”.
(Press the [MENU] button quickly and then press
the [
►
] button for 2 seconds while holding down the
[PRESET] button.)
■
Releasing the limiters
The limiter positions that are set can be released by following
the steps below.
When the position is released, the tally lamp blinks twice.
1
Press one of the [CAM1] to [CAM4] buttons to
select the unit.
2
Release the limiters by taking the steps below.
●
Releasing the upper limit position of the
movement range
Perform the steps in “Basic limiter operations”.
(Press the [MENU] button quickly and then press
the [
▲
] button for 2 seconds while holding down the
[PRESET] button.)
●
Releasing the lower limit position of the
movement range
Perform the steps in “Basic limiter operations”.
(Press the [MENU] button quickly and then press
the [
▼
] button for 2 seconds while holding down the
[PRESET] button.)
●
Releasing the left‑most limit position of the
movement range
Perform the steps in “Basic limiter operations”.
(Press the [MENU] button quickly and then press
the [
◄
] button for 2 seconds while holding down the
[PRESET] button.)
●
Releasing the right‑most limit position of the
movement range
Perform the steps in “Basic limiter operations”.
(Press the [MENU] button quickly and then press
the [
►
] button for 2 seconds while holding down the
[PRESET] button.)
■
Resetting the limiters
To reset the limiters, the currently established settings must
be released.
The limiter positions that are set can be reset by following the
steps below.
1
Release the settings of the limiter positions to
be reset by following the steps in “Releasing
the limiters”.
2
Set the limiter positions by following the steps
in “Setting the limiters”.