![Panasonic AJSDX900P - 24P DVCPRO 50 Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/panasonic/ajsdx900p-24p-dvcpro-50/ajsdx900p-24p-dvcpro-50_service-manual_3824122068.webp)
MECH-27
1-32. LISTA Sensitivity Adjustment and Sensitivity Detection
SPEC
See below
TEST POINT
ADJUST
(ATF GAIN)
Refer to item “6. Table of Test Point for each adjustment item.”.
Click this button , then go to item “6. Table of Test Point for each adjustment item.”.
SD 25M VTR
PLAY (25M and DV mode)
SD 50M VTR
PLAY (25M, 50M and DV mode)
SD 50M CAM
PLAY (25M and 50M mode)
VTR MODE
HD CAM
PLAY (HD LP mode)
SD 25M VTR
SD 50M VTR
NTSC: VFM3581KM(LISTA), VFM3000EDS(DV LISTA)
PAL: VFM3681KM(LISTA), VFM3000EDS(DV LISTA)
SD 50M CAM
NTSC: VFM3581KM(LISTA), PAL: VFM3681KM(LISTA)
TAPE
HD CAM
VFM3781KML
<Specification of confirmation and adjustment according to models>
Adjustment Head and Specification of Sensitivity Value (mV/um) on each mode
HD LP mode
50M mode
25M mode
DV Head
Classified
model
R/P Head
R/P Head
PB(L) Head
R/P Head
PB Head
R/P Head
DVR Head
SD 25M VTR
-----
-----
-----
150±15
150±15
130±30
-----
SD 50M VTR
-----
100±15
100±15
100±15
100±15
-----
130±30
SD 50M CAM
-----
150±15
-----
150±15
-----
-----
-----
HD
CAM 150±15
----- ----- ----- ----- ----- -----
<Sensitivity Adjustment Procedure>
1. Please adjust each items by following the flow chart to perform the LISTA adjustment. SD 50M model is
required adjustment by 25M and 50M mode. HD model is required adjustment by HD LP mode.
2. SD 50M model is required setting on LISTA software and unit to select 25M or 50M mode. 25M and 50M mode
can be changed by press “0” key on LISTA main menu about LISTA software. Please refer to item “6. Table of
Test Point for each adjustment item.” about how to select 25M and 50M mode in the Unit.
3. Set the adjustment mode.(Please refer to item “6. Table of Test Point for each adjustment item.” about how to
set adjustment mode).
Click this button , then go to item “6. Table of Test Point for each adjustment item.”.
4. Connect the each clips of LISTA cable to the test point.
5. Playback the LISTA Alignment Tape.
6. Select the item “<6> ATF Error Signal Monitor” on the LISTA main menu, and after message “1.2% Speed. . .”
appears on the screen, press the Enter key, then sensitivity value and waveform appear on the screen as
shown figure 1-32-1.
7. When the picture is appeared as shown in figure 1-32-1, adjust EVR on service menu so that the “Sens. Value”
on the upper right corner of the screen is within the specification(Please refer to item “6. Table of Test Point for
each adjustment item.” about how to change the numerical value and data renewed of EVR).
Click this button , then go to item “6. Table of Test Point for each adjustment item.”.
8. After finish this adjustment, press the ESC key to return the main menu.
Содержание AJSDX900P - 24P DVCPRO 50
Страница 3: ... 3 ...
Страница 4: ... 4 AJ SDX900E ...
Страница 5: ... 5 ...
Страница 7: ... 7 AJ SDX900P ...
Страница 8: ... 8 AJ SDX900E ...
Страница 9: ...FCD0307NTNK96E440E441 ...
Страница 32: ...INF 22 8 Open a target folder and select mem jcf file And click OK 9 Click OK 10 Click Program ...
Страница 156: ...SCHEMATIC DIAGRAMS NOTE BE SURE TO MAKE YOUR ORDERS OF REPLACEMENT PARTS ACCORDING TO PARTS LIST SECTION 7 ...
Страница 279: ...CBA 1 MOTHER P C BOARD VEP89140A FOIL SIDE FOIL SIDE REF LOC P6 C6 P11 A6 P13 A6 ...
Страница 308: ...CBA 30 FRONT SW P C BOARD VEP80C57A FOIL SIDE COMPONENT SIDE REAR JACK P C BOARD VEP80C52A COMPONENT SIDE FOIL SIDE ...
Страница 310: ...CBA 32 MENU SW P C BOARD VEP80C58A FOIL SIDE COMPONENT SIDE ...
Страница 312: ...PRE REC P C BOARD VEP83608A AJ YA903G FOIL SIDE COMPONENT SIDE CBA 34 ...