ELE-12
2-19. Standard Sensitivity
Fine Adj.
BOARD
PREPROCESS Board
TP
TP103 (R), TP303 (G), TP503 (B)
ADJ.
EVR
F No.
F11 + 1/2 (2,000lux)
CHART
Gray Scale
MODE
CAM
M. EQ.
Oscilloscope
SPEC.
A = 1,000mVp-p
±
10mV
1. Click
the
“18. Standard Sensitivity Fine Adjustment”
of the camera adjustment software.
2. Connect a scope to
TP103
(R-ch) and adjust the Slider
on the PC (EVR)
so that the level
“A”
becomes
1,000mVp-p
±
10mV
.
3. Click
“>>”
.
4. Connect a scope to
TP303
(G-ch) and adjust the Slider
on the PC (EVR)
so that the level
“A”
becomes
1,000mVp-p
±
10mV
.
5. Click
“>>”
.
6. Connect a scope to
TP503
(B-ch) and adjust the Slider
on the PC (EVR)
so that the level
“A”
becomes
1,000mVp-p
±
10mV
.
7. Click
“>>”
.
2-20. Standard Sensitivity
Fine Adj. (P mode)
BOARD
PREPROCESS Board
TP
TP103 (R), TP303 (G), TP503 (B)
ADJ.
EVR
F No.
F11 + 1/2 (2,000lux)
CHART
Gray Scale
MODE
CAM
M. EQ.
Oscilloscope
SPEC.
A = 1,000mVp-p
±
10mV
1. Click
the
“19. Standard Sensitivity Fine Adjustment
P mode”
of the camera adjustment software.
2. Connect a scope to
TP103
(R-ch) and adjust the Slider
on the PC (EVR)
so that the level
“A”
becomes
1,000mVp-p
±
10mV
as shown in 2-19.
3. Click
“>>”
.
4. Connect a scope to
TP303
(G-ch) and adjust the Slider
on the PC (EVR)
so that the level
“A”
becomes
1,000mVp-p
±
10mV
as shown in 2-19.
5. Click
“>>”
.
6. Connect a scope to
TP503
(B-ch) and adjust the Slider
on the PC (EVR)
so that the level
“A”
becomes
1,000mVp-p
±
10mV
as shown in 2-19.
7. Click
“>>”
.
2-21. Pre Clip Voltage Adj.
BOARD
PREAMP Board
TP
TP102 (R), TP302 (G), TP502 (B)
ADJ.
EVR
F No.
Adjustment
CHART
Gray Scale
MODE
CAM
M. EQ.
Monitor TV, Oscilloscope
SPEC.
Saturation Level = 500% (minimum 450%)
1. Click
the
“20. Pre Clip Voltage Adjustment”
of the
camera adjustment software.
2. Connect a scope to
TP102 (R), TP302 (G), TP502 (B)
.
3. Shoot a Gray Scale Chart and adjust the IRIS so that
the video level of the VIDEO OUT becomes 100% at
the white portion.
4. Measure the level of
TP102 (R), TP302 (G), TP502 (B)
(about 400mV) and note it.
5. Set the IRIS to
“F4”
.
6. Adjust the Slider on the PC so that the saturation level
(A) of the
R
signal (
TP102
) becomes more than
5
times
(500%) from 100% level (measured in step 4)
and no saturation blurs (curve) as shown in Figure.
7. Click
“>>”
.
8. Adjust the Slider on the PC so that the saturation level
(A) of the
G
signal (
TP302
) becomes more than
5
times
(500%) from 100% level (measured in step 4)
and no saturation blurs (curve) as shown in Figure.
9. Set the IRIS to
“F2.8”
.
10. Click
“>>”
.
11. Adjust the Slider on the PC so that the saturation level
(A) of the
B
signal (
TP502
) becomes more than
5
times
(500%) from 100% level (measured in step 4)
and no saturation blurs (curve) as shown in Figure.
12. Click
“>>”
.
13. After compleate the adjustment, click
“NORMAL 60I
(for NTSC)
” or “NORMAL 50I
(for PAL)
”
.
- Continued on the next page -
A
OB
PORTION
CENTER
OF NIOSE
Содержание AJSDX900P - 24P DVCPRO 50
Страница 3: ... 3 ...
Страница 4: ... 4 AJ SDX900E ...
Страница 5: ... 5 ...
Страница 7: ... 7 AJ SDX900P ...
Страница 8: ... 8 AJ SDX900E ...
Страница 9: ...FCD0307NTNK96E440E441 ...
Страница 32: ...INF 22 8 Open a target folder and select mem jcf file And click OK 9 Click OK 10 Click Program ...
Страница 156: ...SCHEMATIC DIAGRAMS NOTE BE SURE TO MAKE YOUR ORDERS OF REPLACEMENT PARTS ACCORDING TO PARTS LIST SECTION 7 ...
Страница 279: ...CBA 1 MOTHER P C BOARD VEP89140A FOIL SIDE FOIL SIDE REF LOC P6 C6 P11 A6 P13 A6 ...
Страница 308: ...CBA 30 FRONT SW P C BOARD VEP80C57A FOIL SIDE COMPONENT SIDE REAR JACK P C BOARD VEP80C52A COMPONENT SIDE FOIL SIDE ...
Страница 310: ...CBA 32 MENU SW P C BOARD VEP80C58A FOIL SIDE COMPONENT SIDE ...
Страница 312: ...PRE REC P C BOARD VEP83608A AJ YA903G FOIL SIDE COMPONENT SIDE CBA 34 ...