– 185 –
Chapter 7 Menu Operations — Menu list
Item
Description of settings
[CARD NEAR END ALARM]
Sets whether to output the warning sound at P2 card near end.
[ON], [OFF]
f
Factory setting: [OFF]
[CARD NEAR END TIME]
Sets remaining time to emit the P2 card near end warning.
[2min], [3min]
f
Factory setting: [2min]
[CARD END ALARM]
Sets whether to output the warning sound at P2 card end.
[ON], [OFF]
f
Factory setting: [ON]
[CARD REMAIN/Seg]
Sets the time of one segment (
r
) for the P2 card remaining capacity bar in the display window.
[3min/Seg]:
One segment is three minutes
[5min/Seg]:
One segment is five minutes
f
Factory setting: [3min/Seg]
[BATTERY SETTING]
Item
Description of settings
[BATTERY MODE]
Selects whether to set the near end voltage of a battery.
[AUTO]:
Automatically set.
[MANUAL]:
Manually set.
f
Factory setting: [AUTO]
[HYTRON140 NEAR END]
Selects the near end voltage in steps of 0.1 V when the main menu
→
[I/F SETUP]
→
[BATTERY/
P2CARD]
→
[BATTERY SELECT] is set to [HYTRON140].
[12.0V]…[15.0V]
f
Factory setting: [13.1V]
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[DIONIC 90 NEAR END]
Selects the near end voltage in steps of 0.1 V when the main menu
→
[I/F SETUP]
→
[BATTERY/
P2CARD]
→
[BATTERY SELECT] is set to [DIONIC90].
[12.0V]…[15.0V]
f
Factory setting: [13.7V]
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[ENDURA10 NEAR END]
Selects the near end voltage in steps of 0.1 V when the main menu
→
[I/F SETUP]
→
[BATTERY/
P2CARD]
→
[BATTERY SELECT] is set to [ENDURA10].
[12.0V]…[15.0V]
f
Factory setting: [13.4V]
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[PAG L96e NEAR END]
Selects the near end voltage in steps of 0.1 V when the main menu
→
[I/F SETUP]
→
[BATTERY/
P2CARD]
→
[BATTERY SELECT] is set to [PAG L96e].
[12.0V]…[15.0V]
f
Factory setting: [13.0V]
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[TYPE A FULL]
Selects the voltage for full display in steps of 0.1 V when the main menu
→
[I/F SETUP]
→
[BATTERY/
P2CARD]
→
[BATTERY SELECT] is set to [TYPE A].
[13.0V]…[17.0V]
f
Factory setting: [15.6V]
The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.
[TYPE A NEAR END]
Selects the near end voltage in steps of 0.1 V when the main menu
→
[I/F SETUP]
→
[BATTERY/
P2CARD]
→
[BATTERY SELECT] is set to [TYPE A].
[11.0V]…[15.0V]
f
Factory setting: [13.2V]
The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.
[TYPE A END]
Selects the end voltage in steps of 0.1 V when the main menu
→
[I/F SETUP]
→
[BATTERY/P2CARD]
→
[BATTERY SELECT] is set to [TYPE A].
[11.0V]…[15.0V]
f
Factory setting: [12.5V]
The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.
[TYPE B FULL]
Selects the voltage for full display in steps of 0.1 V when the main menu
→
[I/F SETUP]
→
[BATTERY/
P2CARD]
→
[BATTERY SELECT] is set to [TYPE B].
[13.0V]…[17.0V]
f
Factory setting: [15.9V]
The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.
[TYPE B NEAR END]
Selects the near end voltage in steps of 0.1 V when the main menu
→
[I/F SETUP]
→
[BATTERY/
P2CARD]
→
[BATTERY SELECT] is set to [TYPE B].
[11.0V]…[15.0V]
f
Factory setting: [12.9V]
The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.
[TYPE B END]
Selects the end voltage in steps of 0.1 V when the main menu
→
[I/F SETUP]
→
[BATTERY/P2CARD]
→
[BATTERY SELECT] is set to [TYPE B].
[11.0V]…[15.0V]
f
Factory setting: [12.5V]
The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.