background image

23

GHI 

Type infrared ceramic heaters

 

User’s Manual

GUARANTEE AND SERVICES

PRESERVE THIS WARRANTY 

Type:

Serial no.:

Date of purchasing::

LIMITED GUARANTEE *

The manufacturer guarantee the costumer that the product and its parts are free from 

material and production failures. During normal use the warranty is 2 years. This warranty 

concerns the first retail customer.

The guarantee concerns the costs of laboratory investigations and the parts, which are 

needed for proper operation. The delivery and unforeseeable costs belong also to the 

mending costs and do not contain compensation costs.

Guarantee mending can only be realized by authorized retailer or service centre.

The guarantee does not concerns the following failures, which are caused by: improper 

using,damaging,neglect,accident,lack of maintenance,normal attrition,

transformation,modification and operation influenceable factor,contaminated fuel, installa

-

tion of non-suitable part and mending which is done by not authorized retailer or service 

station.

The regular maintenance is the owner’s responsibility.

The manufacturer does not assume the responsibility in case of accidentally happened or 

directly caused mistake  respectively improper using.

*We reserve the right to change of this specification without extra notification. The guarantee can be applied 

in accordance with above defined. 

Additional guarantee is not accepted.

Guarantee servicing

If your appliance needs guarantee service in that case it can be requested at nearest au-

thorized service station giving in the appliance for repairs. 

Mending services

Take the appliance to the nearest authorized service station. If the device is not under guar

-

antee the service cost will be invoiced to the costumer at defined price. The service centres 

are independent from one another and may have different owners. We reserve the right to 

change of this specification without extra notification. If you would like to contact us the type 

and serial number of device 

always be at hand. In case of other needed information write to the following address:    

  

PAKOLE TRADE Kft.

H-8000 Székesfehérvár, Börgöndi út 8-10.

Tel.: +36 22 316 484                Fax.: +36 22 316 074

Содержание GHI Series

Страница 1: ...NATURAL OR PROPAN GAS WORKING GAS INFRARED CERAMIC HEATERS EN www pakole com 009_022_011_190415_V004_EN Appliance types GHI 7 36 User s Manual...

Страница 2: ...lenoid type VK4125C 2005 S4965R2027 type 10 Electrical connection scheme of HONEYWELL S4965R2027 11 control 11 Optional accessories 11 Suspension 12 Protective distances to be kept considering flammab...

Страница 3: ...ed help or information concerning the appliances for example installation guide or labels etc in that case contact with the manufacturer This appliance must not be used by children and mentally or sen...

Страница 4: ...h during operation despite warming of appliance preserves its stability 2 General Instruction making up of gas and electrical connection in compliance with the specifications it is proposed to connect...

Страница 5: ...TION COMPULSORY USE PROTECTIVE GLOVES If you have to disassemble the unit use special protective gloves Beware of sharp edges inside the unit Beware of roof corners of outdoor units Keep suction grids...

Страница 6: ...face of the ceramics is 850 900 C This surface has a high radiant intensity and quick heat passing The construction of the equipment is not insure to lead away the being combustion product so in this...

Страница 7: ...Type infrared ceramic heaters User s Manual 5 Installation Drawings and dimensions of the appliances control section Reflector mounting bracket This is not the part of the equipment mixing housing Iso...

Страница 8: ...e indications of the static expert 3 Please set the right angle of the unit and fix the srews THE INSTALATION ANGEL OF THE CERAMIC HEATERS TO THE HORIZONTAL PLANE REFERED TO THE CERAMIC SURFACE CAN NO...

Страница 9: ...ce or centrally namely one piece into the gas supply pipe In case of unique solution namely there is pres sure regulator before each appliance before every pressure regulator in case of centrally moun...

Страница 10: ...the diagram which was attached to the appliance ELECTRICAL CONNECTING SPECIFICATIONS The electrical supply 230V 50Hz grounded Approximately 20W electrical performance per appliance The appliance must...

Страница 11: ...rode check the distance to the ceramic surface and to the protective grid Furthermore if it is necessary adjust again the desired maximum 4 mm value to the ceramic Electrodes must not be closer than 1...

Страница 12: ...stallation of appliance must be only executed by qualified service or specialist author ized by retailer The 2 years guarantee of appliance can be ensured only in this case 6 Appliance operation Befor...

Страница 13: ...ecialist or a specialist Check at the beginning of season Maintenances The first adjustment of the appliance must be carried out only from a well educated technician To fulfil this requirement the eas...

Страница 14: ...k ceramic plates Blow them sometimes through by compressed air when it is switched off and cool enough d Check if ceramic plates are broken or not by a survey There is a bright line dur ing glowing po...

Страница 15: ...utomatic control Nozzle pressure is not suitable Replace the solenoid valve Replace the differential switch Check the input and output pres sure on the solenoid valve The ceramic burner ig nites but s...

Страница 16: ...Capacity Stage 1 50 kW Connecting gas pressure mbar mbar NG S gas Propane GHI 7 A 6 6 20 37 50 GHI 11 A 9 9 8 2 20 37 50 GHI 18 A 16 3 13 5 20 37 50 GHI 23 B 19 7 9 85 20 37 50 GHI 36 B 29 8 14 9 20 3...

Страница 17: ...2H3B P 20 30 FI II2H3B P 20 30 FR II2E 3 II2H3P 20 25 30 37 GR II2H3 II2H3P 20 30 37 37 NL I3B P I3P II2L3B P 25 30 50 IE II2H3 II2H3P 20 30 37 37 PL II2E3P II2E3B P 20 37 30 LV II2H3B P 20 30 LT II2H...

Страница 18: ...t output Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 69 4 Envelope insulation class U 0 0 W m2K Radiant factor at minimum heat output RFmin 69 4 Envelope loss factor Fenv...

Страница 19: ...at output Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 70 1 Envelope insulation class U 0 0 W m2K Radiant factor at minimum heat output RFmin 70 1 Envelope loss factor Fen...

Страница 20: ...at output Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 70 7 Envelope insulation class U 0 0 W m2K Radiant factor at minimum heat output RFmin 70 7 Envelope loss factor Fen...

Страница 21: ...at output Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 73 3 Envelope insulation class U 0 0 W m2K Radiant factor at minimum heat output RFmin 73 3 Envelope loss factor Fen...

Страница 22: ...at output Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 73 9 Envelope insulation class U 0 0 W m2K Radiant factor at minimum heat output RFmin 73 9 Envelope loss factor Fen...

Страница 23: ...rized retailer or service station The regular maintenance is the owner s responsibility The manufacturer does not assume the responsibility in case of accidentally happened or directly caused mistake...

Страница 24: ...PAKOLE TRADE Ipari s Kereskedelmi Kft H 8000 Sz kesfeh rv r B rg ndi t 8 10 Honlap http www pakole hu E mail mail pakole hu Tel 36 22 316 484 Fax 36 22 316 074 www pakole hu...

Отзывы: