16
GHI
Type infrared ceramic heaters
User’s Manual
8.
E
nclosurE
* At the GHI-11 appliances the net heat input is 10 kW, with propane gas.
** At the GHI-23 appliances the net heat input is 20 kW, with propane gas.
Type
Input power
Gas consumption
[m
3
/h]
[kg/h]
[kW]
Natural gas
Propane
GHI - 7
6,6
0,7
0,54
GHI - 11*
9,9
1,05
0,82
GHI - 18
16,3
1,73
1,34
GHI - 23**
19,7
2,09
1,63
GHI - 36
29,8
3,16
2,46
Enclosure 2.: gas consumption of GHI heaters
Type
Design
Useful
Capacity
Stage 2 (100%)
[kW]
Useful
Capacity
Stage 1 (50%)
[kW]
Connecting gas pressure
[mbar]
[mbar]
NG/S-gas
Propane
GHI - 7
A**
6,6
-
20
37 / 50*
GHI - 11
A**
9,9
8,2
20
37 / 50*
GHI - 18
A**
16,3
13,5
20
37 / 50*
GHI - 23
B***
19,7
9,85
20
37 / 50*
GHI - 36
B***
29,8
14,9
20
37 / 50*
Enclosure 1.: Type and technical data of infrared heater
* Connecting gas pressure are 30 or 50 mbar in case of Propane gas.
**Execution A is made of one mixing chamber and its 2 stage regulation goes through noozle pressure regulation.
Max. noozle pressure (100%) 16 mbar, Min. noozle pressure (85%) 13,5 mbar.
***Execution B is made of two mixing chamber and its 2 stage regulation goes through switching of one chamber
Max. noozle pressure (100%) 16 mbar, Min. noozle pressure (50%) 16 mbar.