background image

5

GHI 

Type infrared ceramic heaters

 

User’s Manual

Every appliance installation must be satisfied the valid laws and standards. These laws refer to the gas and electrical installation respec

-

tively the ventilation (special specifications refer to park houses, airplane hangars etc).

Standards and laws

CAUTION

!

DANGER

!

CAUTION

!

ELECTRIC

SUPPLY

CAUTION

!

DANGEROUS

OPERATION

CAUTION

!

DANGEROUS

OPERATION

CAUTION

!

HIGH 

TEMPERATURE

 

CAUTION

!

DISCONNECT

POWER LINE

ATTENTION

!

COMPULSORY:

    EARTHING

 

CAUTION

!

DANGER

!

Please observe the following rules during installation, first set-up,  usage or maintance:

ATTENTION

!

ONLY 

QUALIFIED 

PERSON

• 

Installation must be carried out always strictly complying with the current standards of the 

country where the appliance is going to be used and following, of course, the instructions given by 

the producer.

• 

The installation and maintenance operations of the unit can be carried out by qualified and 

trained personnel only.

Qualified service engineers are those having specific technical experience and/or valid license in the field of heating and cooling in

-

stallation for home and industry. In any case, call the Manufacturer office or the closest dealer (www.pakole.com) and ask for further 

informations.

Safety signs

Safe usage

ATTENTION

!

THE USIGE OF 

MOVING EQUIPMENT

 

IS COMPULSORY 

 

ATTENTION

!

COMPULSORY:

USE PROTECTIVE 

GLOVES

 

 

ATTENTION

!

ONLY 

QUALIFIED 

PERSON

ATTENTION

!

FORBIDDEN!

ATTENTION

!

COMPULSORY:

    EARTHING

 

ATTENTION

!

ONLY 

QUALIFIED 

PERSON

CAUTION

!

DANGER

!

CAUTION

!

ELECTRIC

SUPPLY

• 

According to the installation project, install the electric power lines.

• 

Always make sure that the unit and all its electrical parts have been cor-

rectly earthed prior starting up the unit.

CAUTION

!

DANGER

!

ATTENTION

!

ONLY 

QUALIFIED 

PERSON

ATTENTION

!

COMPULSORY:

USE PROTECTIVE 

GLOVES

 

 

• 

If you have to disassemble the unit, use special protective gloves.

• 

Beware of sharp edges inside the unit!

• 

Beware of roof corners of outdoor units!

• 

Keep suction grids always clear!

CAUTION

!

DANGER

!

CAUTION

!

DANGEROUS

OPERATION

ATTENTION

!

FORBIDDEN!

• 

Before cleaning or maintaining the unit, make sure that all electrical parts 

have been switched off, the appliance gas supply chain is closed and wait 

until the appliance cools down. 

CAUTION

!

DANGER

!

CAUTION

!

ELECTRIC

SUPPLY

CAUTION

!

DISCONNECT

POWER LINE

• 

We recommend to install a safety switch which can be easily reached to 

cut off the current, near the unit. Before any cleaning and servicing opera

-

tion, cut off the power line to the unit.

• 

Before  opening  the  unit,  make  sure  that  all  electrical  parts  have  been 

switched off. 

CHECK THE EARTHING !!

ATTENTION

!

COMPULSORY:

    EARTHING

 

CAUTION

!

DANGER

!

• 

This unit is designed to be used for heating purposes only. Any different use is not allowed as it may be dangerous.

• 

Should the unit work in a house where disabled people and/or children live, it must be placed safely away from their 

reach. Always make sure that the access door to the inside control board stay locked.

• 

An incorrect installation can cause damages to people, animals and property. In case of erroneous installation, the 

manufacturer cannot be held responsible for such damages.

• 

The manufacturer cannot be held responsible for such damages by improper uses, errate uses, etc.

• 

Never use the unit to support other equipment.

• 

Never leave tools, spare parts, etc. inside the unit.

• 

Make sure that all inspection panels are closed properly.

• 

Do no expose the unit to inflammable gases.

• 

In case of breakdown or failure: turn unit off, do not try to repair it on your own, call operator.

• 

If you are going to leave the heater switched off for a long time, first make sure that in no way this could cause harm 

to anyone in any way.

ATTENTION

!

FORBIDDEN!

ATTENTION

!

ONLY 

QUALIFIED 

PERSON

Содержание GHI Series

Страница 1: ...NATURAL OR PROPAN GAS WORKING GAS INFRARED CERAMIC HEATERS EN www pakole com 009_022_011_190415_V004_EN Appliance types GHI 7 36 User s Manual...

Страница 2: ...lenoid type VK4125C 2005 S4965R2027 type 10 Electrical connection scheme of HONEYWELL S4965R2027 11 control 11 Optional accessories 11 Suspension 12 Protective distances to be kept considering flammab...

Страница 3: ...ed help or information concerning the appliances for example installation guide or labels etc in that case contact with the manufacturer This appliance must not be used by children and mentally or sen...

Страница 4: ...h during operation despite warming of appliance preserves its stability 2 General Instruction making up of gas and electrical connection in compliance with the specifications it is proposed to connect...

Страница 5: ...TION COMPULSORY USE PROTECTIVE GLOVES If you have to disassemble the unit use special protective gloves Beware of sharp edges inside the unit Beware of roof corners of outdoor units Keep suction grids...

Страница 6: ...face of the ceramics is 850 900 C This surface has a high radiant intensity and quick heat passing The construction of the equipment is not insure to lead away the being combustion product so in this...

Страница 7: ...Type infrared ceramic heaters User s Manual 5 Installation Drawings and dimensions of the appliances control section Reflector mounting bracket This is not the part of the equipment mixing housing Iso...

Страница 8: ...e indications of the static expert 3 Please set the right angle of the unit and fix the srews THE INSTALATION ANGEL OF THE CERAMIC HEATERS TO THE HORIZONTAL PLANE REFERED TO THE CERAMIC SURFACE CAN NO...

Страница 9: ...ce or centrally namely one piece into the gas supply pipe In case of unique solution namely there is pres sure regulator before each appliance before every pressure regulator in case of centrally moun...

Страница 10: ...the diagram which was attached to the appliance ELECTRICAL CONNECTING SPECIFICATIONS The electrical supply 230V 50Hz grounded Approximately 20W electrical performance per appliance The appliance must...

Страница 11: ...rode check the distance to the ceramic surface and to the protective grid Furthermore if it is necessary adjust again the desired maximum 4 mm value to the ceramic Electrodes must not be closer than 1...

Страница 12: ...stallation of appliance must be only executed by qualified service or specialist author ized by retailer The 2 years guarantee of appliance can be ensured only in this case 6 Appliance operation Befor...

Страница 13: ...ecialist or a specialist Check at the beginning of season Maintenances The first adjustment of the appliance must be carried out only from a well educated technician To fulfil this requirement the eas...

Страница 14: ...k ceramic plates Blow them sometimes through by compressed air when it is switched off and cool enough d Check if ceramic plates are broken or not by a survey There is a bright line dur ing glowing po...

Страница 15: ...utomatic control Nozzle pressure is not suitable Replace the solenoid valve Replace the differential switch Check the input and output pres sure on the solenoid valve The ceramic burner ig nites but s...

Страница 16: ...Capacity Stage 1 50 kW Connecting gas pressure mbar mbar NG S gas Propane GHI 7 A 6 6 20 37 50 GHI 11 A 9 9 8 2 20 37 50 GHI 18 A 16 3 13 5 20 37 50 GHI 23 B 19 7 9 85 20 37 50 GHI 36 B 29 8 14 9 20 3...

Страница 17: ...2H3B P 20 30 FI II2H3B P 20 30 FR II2E 3 II2H3P 20 25 30 37 GR II2H3 II2H3P 20 30 37 37 NL I3B P I3P II2L3B P 25 30 50 IE II2H3 II2H3P 20 30 37 37 PL II2E3P II2E3B P 20 37 30 LV II2H3B P 20 30 LT II2H...

Страница 18: ...t output Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 69 4 Envelope insulation class U 0 0 W m2K Radiant factor at minimum heat output RFmin 69 4 Envelope loss factor Fenv...

Страница 19: ...at output Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 70 1 Envelope insulation class U 0 0 W m2K Radiant factor at minimum heat output RFmin 70 1 Envelope loss factor Fen...

Страница 20: ...at output Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 70 7 Envelope insulation class U 0 0 W m2K Radiant factor at minimum heat output RFmin 70 7 Envelope loss factor Fen...

Страница 21: ...at output Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 73 3 Envelope insulation class U 0 0 W m2K Radiant factor at minimum heat output RFmin 73 3 Envelope loss factor Fen...

Страница 22: ...at output Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 73 9 Envelope insulation class U 0 0 W m2K Radiant factor at minimum heat output RFmin 73 9 Envelope loss factor Fen...

Страница 23: ...rized retailer or service station The regular maintenance is the owner s responsibility The manufacturer does not assume the responsibility in case of accidentally happened or directly caused mistake...

Страница 24: ...PAKOLE TRADE Ipari s Kereskedelmi Kft H 8000 Sz kesfeh rv r B rg ndi t 8 10 Honlap http www pakole hu E mail mail pakole hu Tel 36 22 316 484 Fax 36 22 316 074 www pakole hu...