4
GHI
Type infrared ceramic heaters
User’s Manual
•
Make sure that read and understood all the warnings, correct keeping of which can guarantee the safety and faultless operation!
•
During the installation be always circumspect! Follow the valid instructions and recommendations!
•
The appliance can be operated by specified voltage and frequency marked on its data board! The electrical connections and
groundings are prepared as per MSZ EN 60335 standard!
•
Electrical grounding specification: present appliance is equipped with three points grounding connection in the interests of your
protection!
•
It needed to ensure the sufficient quantity of combustion air if the appliance is installed without outside air supply!
•
Keep away the device from the following strong effects: wind, high pressure water jet, rain or dropping water!
•
The appliance must not be used in the open air!
•
The application of device is STRICTLY PROHIBITED in such rooms, which are used for sleep or continuous stay!
•
Keep away the flammable materials from the appliance and its near environment as follows: fuels, thinner or other flammable
fluids and vapours!
•
In the interests of avoiding of dust explosion do not used the device in such rooms where the degree of dust concentration is
high if the device is installed without outside air supply!
•
Before starting of appliance in every case check it in order to detect the possible damages! Never use damaged equipment!
•
In case of Propane-gas operation never install the device in basement or from that lower being rooms! The propane-gas is
heavier specific gravity than the air for this reason in case of possible escaping it will spread towards the lower located rooms!
•
Only use that kind of flexible gas pipe and pressure regulator, which is offered for the appliance by the manufacturer!
•
Before every starting of heater appliance check the condition of connecting gas hose and if it is particularly worn or damaged in
that case exchange it for a new one specified by manufacturer!
•
Preserve the equipment in genuine condition, do not leave it to grow old!
•
Do not use seriously aged equipments any longer!
•
Fix the appliance on such stable surface, which during operation despite warming of appliance preserves its stability!
2.
General Instruction
• making up of gas and electrical connection in compliance with the specifications (it is proposed to connect with the local Build
-
ing Supervisory Authority or Fire-service),
• installation of equipment in accordance with the definitions of this manual,
• installation according to the fire prevention rules,
• supply of the necessary materials/components for installation(which are not belong to appliance),
• planing of air duct systems (ventilation/connections)
• service execution,
• placing the copy of present manual at owner’s disposal,
• assuring of sufficient air circulation around the appliance,
• determination and assuring of needed air for burning, ventilation and blowing in according to the specifications.
The appliance is equipped with data board, which is placed on outside of device’s door. On this data board there are information con
-
cerning the type of device, gas type, electrical connection and flue types.
Installer’s responsibilities
Data board
Category:
II2H3+,II2H3P
Gas type:
Nominal input:
6,6 kW
Pconnecting max.:
1008 14
20 mbar
Pconnecting min.:
Date/place of production
2018.09.13.
60 mbar
PAKOLE Trade Kft.
8000 Székesfehérvár, Börgöndi út
8-10.
Distribute:
SVGW Nr.
12-001-3
16 mbar
Jet pressure:
Naturalgas
NOx:
4
PIN:
1009 CL 1599
IP20
Electrical protection:
PAKOLE Trade Kft.
8000 Székesfehérvár,
Börgöndi út 8-10.
35 W
Electrical power:
Manufacturer
13-10308-P001
Series number:
AC 230V 50Hz
Electrical connection:
Max.current entry:
0,15 A
Type
GHI-7
GB
Targeted country:
1. picture: Data board
ATTENTION! Do not use the appliance in such place where corrosive materials can be in the air!
If the appliance has to be applied in this circumstances outside air has to be ensured for combustion
air!
The manufacturer can not assume responsibility for fault of equipment in case the installation is not happened according to the above.
This responsibility concerns completely the installer. In order to avoid such eventualities, if it is not certain to fit to the building or activity,
ask our colleague for help
Both the owner and the installer have to identify every possible material, which can be present in the building (inflammable materials,cor
-
rosive materials, halo hydrocarbons etc.), and with knowledge of these materials must be planed the heater system!
Corrosive materials