background image

 

FOR YOUR SAFETY READ BEFORE LIGHTING 

 

 

 

 

 

 

LIGHTING INSTRUCTIONS 

 

 

 

 

TO TURN OFF GAS APPLIANCE 

WARNING: 

If you do not follow these instructions exactly, a 

fire or explosion may result causing property damage, 
personal injury or loss of life. 

A. This appliance is equipped with an ignition device which 

automatically lights the pilot. Do not try to light the pilot by hand. 

B. BEFORE LIGHTING smell all around the appliance area for gas. Be 

sure to smell next to the floor because some gas is heavier than 
air and will settle on the floor.  
WHAT TO DO IF YOU SMELL GAS: 
- Do not try to light any appliance. 
- Do not touch any electric switch; do not use any phone in your 
building. 

- Immediately call your gas supplier from a neighbour's phone. Follow 
the gas supplier's instructions. 
- If you cannot reach your gas supplier, call the fire department. 

C. Use only your hand to push in or turn the gas control knob. Never use 

tools. If the knob will not push in or turn by hand, don't try to repair it, 
call a qualified service technician. Force or attempted repair may 
result in a fire or explosion. 

D. Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 
appliance & to replace any part of the control system & any gas 
control which has been under water. 

1. STOP! Read the safety information above on this label. 
2. This appliance is equipped with an ignition device which 

automatically lights the pilot. Do not try to light the pilot by hand. 

3. Push the "On/ Off" switch to turn the fireplace ON. 

- If the burner does light go to step 6. 
- If the burner does not light, complete steps 4 through 5. 
- If the burner will not light or stay lit after several tries, push the 
"On/ Off" switch for the fireplace to OFF, turn off all electric power  

to the fireplace and call your service technician or gas supplier. 
Note: Sufficient time must be allowed for air to escape from lines if 
the unit is being lit for the first time. 

4. Push the "On/ Off" switch to the fireplace Off. 
5.  Allow sufficient length of time (minimum 5 minutes) for any gas in the 

combustion chamber to escape. If you still smell gas, STOP! Follow 
"B" in the safety information above on this label. If you don't smell 
gas, go to step 3. 

6. Set fireplace to desired setting by using hand held remote. 

 

1.

 

Push the "on/ off" switch to the "Off" position.

 

2.  Turn off all electric power to the appliance and remove backup 

batteries if service is to be performed or for extended shutdown. 

                                   Hot while in operation. Do not touch. Severe burns may
result. Keep children, clothing, furniture, gasoline and other liquids having 
flammable vapours away. Keep burner and control compartment clean. See 
installation and operating instructions accompanying the appliance.

                                          L’appareil est chaud lorsqu’il fonctionne. Ne pas 
toucher l’appareil. Risque de brûlures graves. Serveiller les enfants. Garder les 
vêtements, le meubles, l’essence ou autres liquides produisant des vapeurs
inflammables loin de l’appareil. S’assurer que le brûleuret le compartiment des 
commandes sont propres. Voir les instructions d’installation et d’utilisation qui
accompagnent l’appareil.

CAUTION:

ATTENTION

Due to high surface temperatures, keep children, clothing and furniture away. Keep burner and 
control compartment clean. See installation and operating instructions accompanying the 
appliance.

A cause de la temperature elevee des parios, tenir eloignes les enfants, les vetements et les 
meubles. Maintenir propres le brûleur et le compartiment de commande. Voir les instructions 
relatives a l’installation et au fonctionnement qui accompagnent l’appareil.

5052.980-A

The lighting instructions label is located on the back of the gas valve controller caddy (Figure 106). It 

is accessed by removing the front and surround and then pulling the caddy out to reveal the lighting 
instruction label.

Figure 106:  Lighting instructions label location.

 Lighting Instructions 

42

051119-48 100000300

i40 TOFINO

Содержание Tofino Series

Страница 1: ...gases unless a certified kit is used FOR YOUR SAFETY Donotstoreorusegasolineorother flammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try...

Страница 2: ...for SIT Configuration 20 SIT controller 20 SIT gas valve 20 Gas valve for Maxitrol Configuration 21 Maxitrol controller 21 Maxitrol gas valve 21 Gas Pressure Check Output Efficiency 22 22 Gas Pressur...

Страница 3: ...the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CL...

Страница 4: ...psig 3 5 kPa This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pres...

Страница 5: ...ed for servicing the unit must be replaced prior to operating Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by...

Страница 6: ...nsion and or contraction noises during the start up or cool down cycle Similar noises are found with your furnace heat exchanger or cook stove oven Warnings and Cautions WARNING Fire Hazard Can cause...

Страница 7: ...4 D 17 3 8 Use dimension C E 36 1 8 36 1 8 F 22 7 8 22 7 8 G 18 1 4 18 1 4 H 24 1 8 24 1 8 I 27 27 J 34 1 2 34 1 2 K 3 x 4 3 x 4 L 15 5 8 15 5 8 M 25 25 Fireplace Dimensions E I J F G H C D B A K L M...

Страница 8: ...Tofino Insert Backing Plate Dimensions Tofino i40 B A Figure 2 Tofino Surround dimensions HEIGHT WIDTH A B REGULAR 28 42 OVERSIZED 31 44 8 051119 48 100000300 i40 TOFINO...

Страница 9: ...nting the fireplace flue dampener may be blocked open or removed Refractory glass doors screen rails screen mesh and log grates can be removed from the fireplace before installing the insert Also smok...

Страница 10: ...idewall combustibles Refer to Figure 5 20 From center of fireplace to nearest combustible or to backing plate whichever is furthest Side wall Side wall Figure 5 Horizontal clearance to combustibles Ho...

Страница 11: ...adjustments along with the bubble sight Figure 7 to level the Tofino fireplace Adjustable Leveling Bolts Side to side levelling adjustments Rear to front levelling adjustment Bubble sight Figure 6 Le...

Страница 12: ...the flex tubes which will have previously been inserted down the chimney The installer must make sure that the air intake vent and air exhaust vents attach to the correct ports on both the flue adapte...

Страница 13: ...ear terminal CT3 10 to 28 ICC Co linear terminal CT4 10 to 40 Combustion Air Intake Exhaust Vent 13 100000300 051119 48 i40 TOFINO 1 Measure chimney height cut flex liner min 10 as required Mark one p...

Страница 14: ...it takes 2 AAA batteries The SIT Proflame controller Figure 14 is used along with the SIT Proflame gas valve See Figure 38 on page 20 The use of the SIT Proflame controller requires a remote control d...

Страница 15: ...and set aside Installation 1 Place the door over the opening of the fireplace 2 There are two hooks on the top of the handles and two hooks on the bottom of the handle and so the door must be placed...

Страница 16: ...bolts should be removed before installing the rear and side panels so that the bolts protruding from the ceiling do not damage the panels Installation 1 With the above mentioned support bracket and bo...

Страница 17: ...ge of the firebox and gasket Figure 26 as possible as this may damage the panel 3 The rear panel is stabilized once the side panels are in place Stabilize the side panels by installing the glass baffl...

Страница 18: ...a halogen lamp Installing the ceramic baffle 1 With the door removed place one end of the baffle over one of the two upper corners so that the baffle is resting on a rear peg and a front support Figu...

Страница 19: ...in the gas supply line going to the gas control valve to minimize the possibility of any loose scale or dirt within the gas supply line from entering the control valve Check local codes for additional...

Страница 20: ...ch is located on the left hand side of the fireplace for easy access Remove the surround to gain access to the controller SIT gas valve The SIT gas valve assembly is mounted onto a caddy which is loca...

Страница 21: ...the surround to gain access to the controller Maxitrol gas valve The Maxitrol gas valve assembly is mounted onto a caddy which is located on the right hand side of the fireplace for easy access Remov...

Страница 22: ...quirements Input Pressure Natural Gas Propane Minimum 5 0 WC 12 5 WC Maximum 13 9 WC 13 9 WC Manifold Pressure High 3 5 WC 10 WC Low 1 7 WC 2 7 WC Tofino i40 SIT Version Gas Orifice Output NG Front AC...

Страница 23: ...rts using a 3 16 Allan key 3 If necessary attach brass test extensions to the test ports Extensions are not included Figure 43 4 Attach one end of hoses to brass extensions and the other end to the pr...

Страница 24: ...ly to reduce the speed of the intake air and thus calm the flames to a more natural look Over closure of this damper could cause an insufficient air supply to the fire which would result in flames tha...

Страница 25: ...o venturi adjustments Venturi closed Figure 48 Venturi closed Venturi opened Figure 49 Venturi opened Note The venturi settings on the Tofino i40 units come preset from the manufacturer Units that use...

Страница 26: ...lot and rectifier flame so that it is not impeded Avoid dumping entire contents of bag onto the burner tray as fine glass particles at the bottom of the bag can block burner ports and hamper the funct...

Страница 27: ...ase piece Figure 54 Log set base pieces Figure 55 Log number 1 Figure 56 Log number 2 Figure 57 Log number 3 Figure 58 Log number 4 Figure 59 Log number 5 Figure 60 Log number 6 Figure 61 Log number 7...

Страница 28: ...igure 66 This gap is required for air flow Also secure the Ember pieces Retainer Figure 64 along the back of the rear burner This will help to keep the ember pieces from spilling over from the burner...

Страница 29: ...ace Figure 69 Front mesh guard Figure 70 Front mesh guard in place 3 Place the front mesh guard Figure 69 along the front edge of the front burner Secure with supplied screws Fit the guards gap around...

Страница 30: ...side base piece on top of the right side mesh guard as shown in Figure 73 The base pieces in addition to adding an aesthetic dimension to the overall appearance help to complete an enclosure for holdi...

Страница 31: ...og is up against the rear wall Figure 77 9 Distribute a thin layer of ember pieces Figure 62 onto the front and rear burner trays Figure 78 Place extra ember pieces on the thin but noticeable gaps bet...

Страница 32: ...bottom of this log can be inserted into the hole of the right hand base piece The front tip of the log should be very close to or just touching the center base piece Figure 82 12 There is a location...

Страница 33: ...g Figure 60 so that the top end rests on top of the 1st log and the bottom end rests against the left wall panel and left base piece Figure 85 The bottom end should be close to the front edge of the l...

Страница 34: ...of the ember wool Figure 63 so that they are not compressed or compacted and spread them in front of the logs to finish Figure 87 Spread out ember wool in this area Figure 87 Completed log set with em...

Страница 35: ...F Switch cable is plugged into the SIT module jack X8 as shown in Figure 88 Connector X8 Figure 88 SIT manual switch connection at SIT module Note regarding batteries for the SIT module Figure 88 Inst...

Страница 36: ...screw into place Figure 90 Note The SIT remote handset and receiver can be paired at this time before the surround backing plate and surround are installed in their final locations See Pairing the SIT...

Страница 37: ...F switch assembly Figure 92 Switch connector at control module Figure 93 Positioning the switch behind the backing plate opening slot 37 100000300 051119 48 i40 TOFINO To install ON OFF Switch 1 Check...

Страница 38: ...e ON OFF Flame UP Down Figure 95 On Off switch location for Maxitrol units 38 051119 48 100000300 i40 TOFINO 3 Use a 2mm Allen key to fasten the switch to the backing plate Figure 94 4 Install the sur...

Страница 39: ...orative front and backing plate Figure 102 and Figure 103 removed press the button marked PRG on the caddy and press the program button once Figure 98 The module will beep 3 times indicating that it i...

Страница 40: ...n is located here Figure 101 4 Press and hold the receiver s reset button Figure 101 until you hear two 2 beeps After the second longer beep release the reset button Within the subsequent 20 seconds p...

Страница 41: ...before seating the backing plate onto the fireplace 2 Place the backing plate onto the fireplace by inserting its four hooks into the four slots on the fireplace frame Figure 104 3 Install the surrou...

Страница 42: ...allowed for air to escape from lines if the unit is being lit for the first time 4 Push the On Off switch to the fireplace Off 5 Allow sufficient length of time minimum 5 minutes for any gas in the c...

Страница 43: ...soot buildup If excessive buildup of soot is present have a qualified service person inspect and adjust unit for proper combustion Clean logs and burner with a brush or vacuum cleaner paying close at...

Страница 44: ...wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing LAMP COMFORT FAN PILOT BURNER ON OFF Figure 109 SI...

Страница 45: ...re Cable Thermocurrent Cable SW Thermocurrent Cable TC ON OFF Flame UP DOWN Antenna RESET Button Receiver Ignition Cable Main Burner Pilot Burner Figure 110 Maxitrol wiring diagram Wiring Diagram for...

Страница 46: ...e wall 20 Hearth in front of appliance 0 Under appliance 0 Objects in front of appliance 36 WARNING Improper installation adjustment alteration service or maintenance can cause injury or property dama...

Страница 47: ...Rating label location The rating label for the Tofino is located on the left hand outside wall of the insert Figure 111 Rating label location 47 100000300 051119 48 i40 TOFINO...

Страница 48: ...LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer Web site www pa...

Отзывы: