background image

HOW TO ADJUST THE
SPEAKER AND
MICROPHONE VOLUME

HOW TO ADJUST THE
LCD DISPLAY

HOW TO ADJUST THE
PULSE SENSITIVITY

HOW TO CHECK THE
NUMBER OF TENANTS
PROGRAMMED IN THE
SYSTEM

The speaker volume and microphone are factory preset. See figure 2.1 to locate the
speaker volume adjustment pot (VR2). 

• 

COUNTER-CLOCKWISE TO INCREASE

• CLOCKWISE TO DECREASE

If you hear a "feedback" when you close the face plate, decrease the volume.

To locate the LCD adjustment pot, see figure 2.1 (VR3).

CLOCKWISE TO INCREASE 

• COUNTER-CLOCKWISE TO DECREASE

To locate the Pulse Sensitivity adjustment pot, see figure 2.1 (VR1).The Pulse sensitivity
is factory preset. 

• 

COUNTER-CLOCKWISE TO INCREASE THE PULSE SENSITIVITY. 

An 

Adjustment is necessary if the LED flashes or ON if the system is in a dial 

tone mode (press  #, to get a dial tone), 

• COUNTER CLOCKWISE TO DECREASE,

LED should goes off if the system

is in dial tone mode.

You cannot program the tenant's directory more than the system capacity. An accurate
tenant's record is essential. You must delete any unused tenant's directory to free the
system's memory. You may check the total number of tenant in the system locally (using
the unit keypad or optional AeGIS 9000 Management Software. The number of tenants
may not be accurate if the tenant name is not programmed. 

The steps below are to

check the number of tenants in the system locally.

See the optional AeGIS 9000

Series Management Software to check the number of tenants in the systems.

Step 1

Log on to programming mode by pressing the 0 and # simultaneously then 
release, the display stops scrolling and shows

Step 2

Press 

then the display shows

then the display shows

XXXX= total number of tenant 

programmed

NOTE:

A directory without a tenant name will not be counted in the total 
number of tenant.

Pach and Company

Chapter 4

Page 36

AeGIS 9000 Series

SYSTEM’S OPERATION

SELECT PROGRAM
ENTER: _ _  PRESS #

%DATABASE SORTING%
Please Wait   . . . .

DIR  #  USED:   XXXX
Please Wait   . . . .

Содержание AeGIS 91000CR1000

Страница 1: ...AeGIS 9000 Series Installation and Programming Manual PACH AND COMPANY 941 Calle Negocio Phone 1 888 678 7224 www pach co com San Clemente CA 92673 Fax 949 498 6879 REV 7 0 ...

Страница 2: ......

Страница 3: ... Schedule 16 16 Reinitialize Time Zones Schedules 17 17 Reinitialize Auto Unlock Schedules 18 18 Reinitialize Holiday Schedules 18 19 Reinitialize Events Recording 18 20 New Tenant Code 19 21 Modify Tenant Code 19 22 Delete A Tenant Code 20 23 Clear All Tenants 20 24 Card and Code 21 26 Facility Code 21 27 RS 232 or Modem 22 28 Directory Digit 22 29 Alarm Delay 22 30 Add Keypad Access Code and Car...

Страница 4: ...ss Code 32 How to to Use the Alarm Telephone Number 32 Relay 2 Modes 32 How the Door Sensor or Shock Sensor Operates 33 How to Adjust the Speaker and Microphone Volume 35 How to Adjust the LCD Display 35 How to Adjust the Pulse Sensitivity 35 How to Check the Number of Tenants Programmed in the System 35 Chapter 5 Trouble Shooting Guide 36 General FCC Requirements 39 Quick Guide 40 ...

Страница 5: ...formation herein implied Pach and Company does not assume any liability for any damages which may arise in installation or use of the AeGIS 9000 Series Pach and Company does not assume liability for any incompatibility between the AeGIS 9000 Series and users devices Pach Company reserves the right to make changes without prior notice to any products in order to improve reliability function or desi...

Страница 6: ...enants MUST have a telephone to allow remote visitor access The system parameters and tenants data will be entered via the keypad and the LCD provides easy display EEPROM technology is used for AeGIS 9000 Series The tenant database will not be lost during a power failure Standard features Program and store the tenant s name directory code telephone number and personal access code Unlocking door or...

Страница 7: ... Power Input 5 0 VDC Regulated Power by the AeGIS 9000 Series 5VDC regulated or 6 0 24 VDC Unregualted not supplied Transmit Frequency 318 Mhz Bandwith 300 Khz minimum Read Range 5 500 feet Accessories and Replacement Parts Pach and Company Chapter 1 Page 2 AeGIS 9000 Series GETTING STARTED PART NUMBER PART NUMBER FFM9 full slush mounting ring for 9000FF Series AHHT2 26 bit dual button hand held t...

Страница 8: ...the warranty All implied warranties including warranties for marketability as well as implied warranties for suitability are valid only until the warranty expires or is voided whichever comes first This Pach and Company Limited Warranty is in lieu of all other warranties express or implied and all Pach and Company warranties are subject but not limited to the following conditions I NEW PRODUCT POL...

Страница 9: ...es the right to repair the product or replace a warranted product with a like product of equal value in the event original product cannot be repaired 6 Distributors and or Dealer Installer must first obtain a Return Merchandise Authorization RMA number from Pach and Company Technical Department before returning any product to factory for repair whether under warranty or not No returns accepted wit...

Страница 10: ...epair center 9 Pach and Company warranty does not guarantee any product to be free of operation error or service interruption in any way during the course of daily product operation 10 Pach and Company is not responsible for time travel and or labor costs of any distributor and or dealer installer includ ing but not limited to any expenses to install uninstall or reinstall hardware software firmwa...

Страница 11: ...ibutor and or Dealer Installer are responsible for all shipping charges incl freight and insurance fees for products shipped to Pach and Company repair center 9 Pach and Company warranty does not guarantee any product new or repaired to be free of operation error or service interruption in any way during the course of daily product operation 10 Pach and Company is not responsible for time travel a...

Страница 12: ...uirements as specified in this chapter Figure 2 1 Wiring Block Diagram Pach and Company Chapter 2 Page 4 AeGIS 9000 Series INSTALLATION 2 3 4 5 6 7 1 8 RED BLACK WHITE GREEN 9 INPUT FOR 26 BIT READER RADIO READER OR FINGER PRINT READER 2nd relay can be connected as Mode 1 Door Control Mode 2 A Shunt Mode 3 An Alarm Mode 4 CCTV switch Battery Backup To RS1 To RS2 ...

Страница 13: ...if ASP1 Surge Protector is used If a PBX line is used connect the AeGIS to the analog PBX s extension to dial the extensions within the PBX Do not connect to a PBX s Digital Port NOTE The AeGIS 9000 Series only works behind the PBX to dial extensions no pause can be programmed on the AeGIS 9000 Series to dial the outside line DOOR STRIKE OR ELECTRICAL STRIKE The AeGIS 9000 Series provides TWO rela...

Страница 14: ...e customer supply The life of the battery is approximately 8 hours in idle mode Use two conductors 18 gauge shielded stranded wires WARNING The connection is polarity sensitive Connect the battery terminal to the connector labeled BAT on the AeGIS and the battery terminal to the connector labeled LCOM on the AeGIS See figure 2 1 for wiring diagram NIGHT LIGHT 14V 0 080A 15 000 Average life hours l...

Страница 15: ...232 DB9 Port The port is used for local programming via AeGIS 9000 Series Management Software See the wiring diagram below for RS 232 connector wiring diagram Figure 2 4 RS 232 CONNECTOR 11 Pach and Company Chapter 2 Page 7 AeGIS 9000 Series INSTALLATION ...

Страница 16: ...mode 3 2 RS 232 AND REMOTE PROGRAMMING VIA THE PACH AND COMPANY MANAGEMENT SOFTWARE See the enclosed CD for Manual You may install up to eight systems on the same phone line but if Pach and Company Management Software is used you must follow the requirements below A Maximum of four AeGIS 9000 Series can be connected on the same phone line for remote programming via modem and eight systems on the s...

Страница 17: ...ode to program different field from the table or press to exit the programming mode and the display shows Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function code 01 then press the display shows Step3 Enter the talk time 10 240 seconds then press the display shows Step 4 Select another Function Code to program different field from the table or press to exit th...

Страница 18: ... Step 2 Enter Function code 03 then press the display shows Step 3 Enter the Lock Out Count value 1 9 then press the display shows Step 4 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function code 04 then press the display shows Step 3 Enter 1 for Tone an...

Страница 19: ...ode see section 3 1 The display shows Step 2 Enter Function Code 07 then press and the display shows Step 3 Enter 1 to ENABLE and 0 to DISABLE then press the display shows Step 4 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 08 then press and...

Страница 20: ...e Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 11 then press and the display shows 09 ALARM TELEPHONE NUMBER To alert the manager by calling the phone number programmed in case Door has been forced open Door has been left ajar for over the time set on Function Code 29 Invalid keypad code or card are entered more than the lock out count programmed i...

Страница 21: ...ter you have entered on each segment then the display shows Step 5 Enter 16 characters on the third segment by rewriting the existing message or pressing to clear the segment and reenter the message press on every character you have entered and press after the last character you have entered on each segment then the display shows Step 6 Select another Function Code to program different field from ...

Страница 22: ... military format then press and enter the MINUTE then press the display shows Step 4 Enter 1 for DAYLIGHT SAVING ZONE or 0 for NON DAYLIGHT SAVING ZONE DO NOT PRESS the display shows Your display may not look identical Step 5 Enter 1 if the date is CORRECT and proceed to step 8 or 0 if it is NOT CORRECT the display shows MM Month DD Date YYYY Year D Day of Week see table 3 1 Step 6 Enter the curre...

Страница 23: ...4 IF 1 is entered to ADD the display shows proceed to step 5 IF 0 is entered to DELETE the display shows proceed to step 7 Step 5 Enter the START TIME HOUR military time format then press and enter the MINUTES then press the display shows Step 6 Enter the DAY OF THE WEEK 1 Mon 2 Tue 3 Wed 4 Thu 5 Fri 6 Sat 7 Sun then press the display shows Step 7 Enter 1 for YES then press and return to step 2 or...

Страница 24: ...ss and return to step 2 or 0 for NO then press and the display shows Step 7 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 15 then press and the display shows Step 3 Enter schedule number 0 9 then press the display shows Step 4 Enter 1 to ADD ...

Страница 25: ... Enter 1 for YES then press and return to step 2 or 0 for NO then press and the display shows Step 10 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 16 then press and the display shows Step 3 Press 1 for YES or 0 for NO then press the display ...

Страница 26: ...on Code 18 then press and the display shows Step 3 Press 1 for YES or 0 for NO then press the display show Step 4 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 19 then press and the display shows Step 3 Press 1 for YES or 0 for NO then press ...

Страница 27: ...ering each character and press after entering the last character see figure 3 1 for keypad correlation the display shows Step 5 Enter a telephone number up to 11 digit then press enter the display shows Step 6 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter ...

Страница 28: ...y shows if tenant code exists proceed to step 5 OR if tenant code does not exist then the display shows proceed to step 5 Step 5 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 23 then press and the display shows Step 3 Enter 1 for YES then pre...

Страница 29: ...ramming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 24 then press and the display shows Step 3 Enter 0 KEYPAD ACCESS CODE or 1 CARD ACCESS KEYPAD ACCESS CODE then press the display shows Step 4 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see sec...

Страница 30: ...ess the display shows Step 5 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 28 then press and the display shows Step 3 Enter the directory digit 2 3 or 4 digit then press the display shows then the display shows Step 4 Select another Function ...

Страница 31: ...ystem then press the display shows if door 2 is set for mode 1 door control If door 2 is set other than mode 1 proceed to step 6 Step 5 Enter 1 Relay 1 Door 1 2 Relay 2 Door 2 3 Both then press the display shows Step 6 Enter 1 3 then press the display shows Step 7 Enter the Time Zone s programmed on Function Code 13 0 9 then press the display shows Step 8 Enter 1 YES then press and proceed to step...

Страница 32: ... Reader installed on the system then press the display shows if door 2 is set for mode 1 door control If door 2 is set other than mode 1 proceed to step 6 Step 5 Enter 1 Relay 1 Door 1 2 Relay 2 Door 2 3 Both then press the display shows Step 6 Enter 1 3 then press the display shows Step 7 Enter the Time Zone s programmed on Function Code 13 0 9 then press the display shows Step 8 Enter 1 YES then...

Страница 33: ... is valid or Press to CANCEL and proceed to step 5 OR if the keypad access code is invalid THEN display shows Step 5 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 33 then press and the display shows Step 3 Enter 1 YES then press the display s...

Страница 34: ...n 3 1 The display shows Step 2 Enter Function Code 40 then press and the display shows Step 3 Enter 0 NO or 1 YES then press the display shows Step 4 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 41 then press and the display shows Step 3 Ent...

Страница 35: ...000 Series PROGRAMMING PBX Area No _ _ _ SELECT PROGRAM ENTER _ _ PRESS SELECT PROGRAM ENTER _ _ PRESS Open Door1No 0 9 ENTER _ PRESS If relay 2 door 2 is set for Mode 1 door control the display shows proceed to step 4 if the number is already used the display shows return to step 3 if relay 2 is set for Mode 4 CCTV Switch the display shows proceed to step 4 if the number is already used the displ...

Страница 36: ...e section 3 1 The display shows Step 2 Enter Function Code 50 then press and the display shows Step 3 Enter 1 TO CLEAR or 0 TO CANCEL then press the display shows Step 4 Wait for a few minutes the more tenants programmed the longer it takes to erase the memory the the display shows Step 5 Select another Function Code to program different field from the table or press to exit the programming mode S...

Страница 37: ...ode associated with the name Step 4 Press 3 to proceed to next tenant name and return to step 3 or proceed to step 5 or press and the display shows Step 5 Select another Function Code to program different field from the table or press to exit the programming mode Pach and Company Chapter 3 Page 29 AeGIS 9000 Series PROGRAMMING NNNNNNNNNNN DIR No XXXX SELECT PROGRAM ENTER _ _ PRESS ...

Страница 38: ... 1 or 8 default setting to unlock relay 2 door 2 2 A DIRECT CALL You must know the tenant directory number to use a direct call The tenant directory number can be associated with apartment number suite number etc Step 1 Press and wait for a dial tone the display shows N tenant code directory code number of digit Step 2 Press the 2 3 or 4 digit directory number the system will initiate the call the...

Страница 39: ... setting to unlock relay 1 door 1 or 8 default setting to unlock relay 2 door 2 Step 1 Press then the screen stops scrolling if the screen is still scrolling repeat this step Step 2 Press a valid keypad access code and the door will unlock If the keypad access code is invalid the display shows NOTE If invalid codes are entered more than the number program on Function Code 03 the display shows the ...

Страница 40: ...r programmed A phone number on Function Code 29 The system displays shows If invalid keypad access code card access or keypad access code card access are used The system will call the phone number programmed on Function Code 09 and the receiving party will hear continuous beeps This feature is not applicable if Relay 2 is set as MODE 3 on Function Code 08 Relay 2 is an auxiliary relay It can be se...

Страница 41: ...lt setting on his or her phone to turn ON the camera and monitor the visitors at the system The number can be changed see Function Code 43 Step 4 When finished press 7 default setting to turn OFF the camera See Function Code 43 Step 5 Repeat step 3 4 if you need to turn the camera ON and OFF The door sensor switch or shock sensor is an option see figure 2 1 for wiring diagram Door sensor is availa...

Страница 42: ...if Door 1 is still opened after the open interval set on Function Code 02 on relay 1 has expired Or door 1 is forced open Relay 2 will be activated and the display shows You may connect an emergency light an alarm device or a buzzer on relay 2 The sce narios above are valid until the problems are corrected MODE 4 RELAY 2 AS A CCTV SWITCH The system will make double beeps every 60 seconds if Door 1...

Страница 43: ... is in dial tone mode You cannot program the tenant s directory more than the system capacity An accurate tenant s record is essential You must delete any unused tenant s directory to free the system s memory You may check the total number of tenant in the system locally using the unit keypad or optional AeGIS 9000 Management Software The number of tenants may not be accurate if the tenant name is...

Страница 44: ...clip connector on the speaker and microphone connector must be facing inside the board Check the brown and black wires make sure they are soldered into the microphone Turn the system s power OFF and disconnect the speaker connector from the board Set your meter to Ohm and use 50 Ohm scale or higher Place the two probes into the speaker and polarity not important and the meter should should read be...

Страница 45: ...nect the phone line from the AeGIS system and connect a standard phone into the phone line and try to place a call Check the phone number on the system programming Check the phone line and make sure the telephone terminal box is grounded Check if the problem occurs on all tenants Disconnect the phone line from the AeGIS system and connect a standard phone into the phone line and try to place a cal...

Страница 46: ...lly Open strike is used the meter will read as an open circuit or RC1 and NC1 or RC2 and NC2 if Normally Close strike is used your meter will read about 0 value Place a call from the system to one of the tenants and tell the tenant to press 9 or 8 and you should get the following results Your meter should read about 0 value if RC1 and NO1 or RC2 and NO2 contacts are used otherwise the system s rel...

Страница 47: ... devices you can connect to your telephone line your tele phone company will provide you upon request In the unlikely event your AeGIS system develops a problem IMMEDIATELY DISCONNECT IT FROM YOUR TELEPHONE LINE to avoid harmful causes to the telephone network If repairs are ever needed on your AeGIS system ONLY Pach and Company technician should perform them Please contact our Toll Free Technical...

Страница 48: ...E AeGIS 9000 Series Dial the AeGIS phone number you hear ONE SHORT BEEP if you are connected then press to communicate with the visitor and press 9 or to unlock the door This feature is not applicable if multi systems are connected on the same phone line See manual for more detail FUNCTION CODE TABLE CODE DESCRIPTION CODE DESCRIPTION 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 Exit th...

Страница 49: ......

Отзывы: