![PACH & COMPANY AeGIS 91000CR1000 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/pach-and-company/aegis-91000cr1000/aegis-91000cr1000_installation-and-programming-manual_745834017.webp)
00
REPLACE SYSTEM MASTER
CODE
(
Default setting is 0000
)
Master Code is used to log on to
programming mode, not to unlock
door or gate.
01
CHANGE TALK TIME
(
Default setting is 090 Seconds
)
Minimum setting is 10 seconds and
Maximum setting is 240 seconds.
Talk Time between the tenant and
visitor. The talk time is also a
hang-up time.
02
OPEN INTERVAL RELAY 1 and
RELAY 2
(
Default setting is 012 Seconds
)
Minimum setting is 04 seconds and
Maximum setting is 99 seconds.
Unlock Time for Door 1 and Door 2.
Step 1
Log on to programming mode (see section 3.1). The display shows
Step 2
Enter Function code 00, then press #, the display shows
Step 3
Enter the new 4-digit Master Code then press # the display shows
If you press * the display shows
Ignore the message, and your existing Master Code will remain in the system.
Step 4
Select another Function Code to program different field from the table or
press * to exit the programming mode and the display shows
Step 1
Log on to programming mode (see section 3.1). The display shows
Step 2
Enter Function code 01, then press #, the display shows
Step3
Enter the talk time (10-240 seconds) then press #, the display shows
Step 4
Select another Function Code to program different field from the table or
press * to exit the programming mode.
Step 1
Log on to programming mode (see section 3.1). The display shows
Step 2
Enter Function code 02, then press #, the display shows
Step 3
Enter
1 for relay 1 (door 1)
or
2 for relay 2 (door 2)
then press #, the
display shows
Pach and Company
Chapter 3
Page 9
AeGIS 9000 Series
PROGRAMMING
FUNCTION CODE
LOCAL PROGRAMMING
SELECT PROGRAM
ENTER: _ _ PRESS #
MASTER CODE: 0000
NEW: _ _ _ _ # ENT
SELECT PROGRAM
ENTER: _ _ PRESS #
** CODE ERROR
NOTHING CHANGED!
DIR # USED: XXXX
Please Wait . . . .
SELECT PROGRAM
ENTER: _ _ PRESS #
TALK TIME, 10-240
ENTER: _ _ PRESS #
SELECT PROGRAM
ENTER: _ _ PRESS #
SELECT PROGRAM
ENTER: _ _ PRESS #
Set which Relay?
(1 or 2): _