seconds. The authorized person will hear continuous beeps when
the phone is answered. The display shows
The scenarios above are valid until the problems are corrected.
MODE 2 (RELAY 2 AS A SHUNT)
The system will make double beeps every 60 seconds if :
• Door 1 is still opened after the open interval set on Function Code 02 on relay
1 has expired.
• Or door 1 is forced open. If Function Code 09 is programmed to call a phone
number, the system will§ Make double beeps every 60 seconds.
• Call to the number programmed on Function Code 09 every 60 seconds. The
authorized person will hear continuous beeps when the phone is answered.
The display shows
The scenarios above are valid until the problems are corrected
MODE 3 (RELAY 2 AS AN ALRM TIMER)
The system will make double beeps every 60 seconds if :
• Door 1 is still opened after the open interval set on Function Code 02 on relay
1 has expired. }
• Or door 1 is forced open. Relay 2 will be activated and the display shows
You may connect an emergency light , an alarm device or a buzzer on relay 2.The sce-
narios above are valid until the problems are corrected.
MODE 4 (RELAY 2 AS A CCTV SWITCH)
The system will make double beeps every 60 seconds if :
• Door 1 is still opened after the open interval set on Function Code 02 on relay
1 has expired.
• Or door 1 is forced open. If Function Code 09 is programmed to call a phone
number, the system will
• Make double beeps every 60 seconds.
• Call to the number programmed on Function Code 09 every 60
seconds. The authorized person will hear continuous beeps when
the phone is answered. The display shows
The scenarios above are valid until the problems are corrected.
Pach and Company
Chapter 4
Page 35
AeGIS 9000 Series
SYSTEM’S OPERATION
ALARM ACTIVATED
ALARM ACTIVATED
ALARM ACTIVATED
ALARM ACTIVATED