![OutBack Power SmartRE 2500 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/outback-power/smartre-2500/smartre-2500_installation-manual_1660807005.webp)
Important Safety Instructions
900-0033-01-00 Rev A
3
Personal Safety
WARNING: Personal Injury
¾
This equipment weighs over 100 lbs (45 kg). Use safe lifting techniques
when lifting this equipment as prescribed by the Occupational Safety and
Health Association (OSHA) or other local codes.
¾
Use standard safety equipment such as safety glasses, ear protection, steel-
toed safety boots, safety hard hats, etc. as prescribed by the Occupational
Safety and Health Association (or other local codes) when working on this
equipment.
¾
Use standard safety practices when working with electrical equipment
(e.g., remove all jewelry, use insulated tools, wear cotton clothing, etc.)
¾
Never work alone when installing or servicing this equipment. Have
someone nearby that can come to your aid if necessary.
SmartRE System Safety
WARNING: Lethal Voltage
¾
Review the system configuration to identify all possible sources of energy.
Ensure ALL sources of power are disconnected before performing any
installation or maintenance on this equipment. Confirm that the terminals
are de-energized using a validated voltmeter (rated for a minimum
1000 Vac and 1000 Vdc) to verify the de-energized condition.
¾
Do not perform any servicing other than that specified in the installation
instructions unless qualified to do so or as instructed to do so by OutBack
Power Systems Technical Support personnel.
WARNING: Burn Hazard
Internal parts can become hot during operation. Do not remove the cover
during operation or touch any internal parts. Be sure to allow them sufficient
time to cool down before attempting to perform any maintenance.
WARNING: Fire Hazard
¾
In residential installations: check for multi-wire branch circuit wiring at the
location for the installation. A possible fire hazard can exist if 120 Vac only
sources (such as inverters and generators) are wired incorrectly into
120/240 Vac panels containing multi-wire branch circuits. Consult the local
electric code for assistance.
¾
Do not place combustible or flammable materials within 12 feet (3.7 m) of
the equipment.
¾
Use only the recommended cable sizes (or greater) for AC and DC
conductors in compliance with local codes. Ensure all conductors and
connections are in good condition. Do not operate the unit with damaged
or substandard cabling.
Содержание SmartRE 2500
Страница 1: ...Installation Manual...
Страница 19: ...Planning 900 0033 01 00 Rev A 17 Dimensions Figure 6 Enclosure Dimensions...
Страница 28: ...Installation 26 900 0033 01 00 Rev A Figure 14 Correct Placement for Vertical Installations...
Страница 29: ...Installation 900 0033 01 00 Rev A 27 Removing the Interior Cover Figure 15 Removing the Interior Cover...
Страница 54: ......
Страница 56: ...Wiring Configurations 54 900 0033 01 00 Rev A This page intentionally left blank...
Страница 64: ...Wiring Configurations 62 900 0033 01 00 Rev A This page intentionally left blank...