![OutBack Power SmartRE 2500 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/outback-power/smartre-2500/smartre-2500_installation-manual_1660807032.webp)
Installation
30
900-0033-01-00 Rev A
DC Connections
Table 5
DC Conductor Size and Torque Requirements
DC Terminal
Acceptable Conductor
Size Range
Conductor Size
(Recommended)
Torque
Requirements
Breaker
Size
Battery Positive (+)
#6 AWG (13.3mm
2
) –
1/0 AWG (53.5 mm
2
)
#1/0 AWG
50 in-lb (5.7 Nm)
125 Adc
Battery Negative (–)
(Shunt A)
#6 AWG (13.3mm
2
) –
1/0 AWG (53.5 mm
2
)
#1/0 AWG
50 in-lb (5.7 Nm)
N/A
PV Positive (+)
#6 AWG (13.3mm
2
) –
1/0 AWG (53.5 mm
2
)
#6 AWG (13.3mm
2
)
35 in-lb (4 Nm)
80 Adc
PV Negative (–)
(DC Negative Bus Bar)
#6 AWG (13.3mm
2
) –
1/0 AWG (53.5 mm
2
)
#6 AWG (13.3mm
2
)
35 in-lb (4 Nm)
N/A
Figure 18
DC Connections
DC Negative (–)
Bus Bar
Shunt B
DC Negative (–)
Bus Bar
Shunt A
DC Breaker (B)
(125 Adc)
PV Breaker (PV +)
(80 Adc)
GFP/Batt +
Internal components shown may vary from model to model. Factory wiring is not shown.
Содержание SmartRE 2500
Страница 1: ...Installation Manual...
Страница 19: ...Planning 900 0033 01 00 Rev A 17 Dimensions Figure 6 Enclosure Dimensions...
Страница 28: ...Installation 26 900 0033 01 00 Rev A Figure 14 Correct Placement for Vertical Installations...
Страница 29: ...Installation 900 0033 01 00 Rev A 27 Removing the Interior Cover Figure 15 Removing the Interior Cover...
Страница 54: ......
Страница 56: ...Wiring Configurations 54 900 0033 01 00 Rev A This page intentionally left blank...
Страница 64: ...Wiring Configurations 62 900 0033 01 00 Rev A This page intentionally left blank...