3 Intended use
The safe use of the product can only be ensured in case of intended use in accordance with the information con
tained in these instructions for use. The user is ultimately responsible for accident-free operation.
3.1 Indications for use
The sports wheelchair is exclusively suited for temporary use in wheelchair sports on smooth floor coverings.
Any other or additional use is considered improper. Using the sports wheelchair outdoors or for overcoming
obstacles is prohibited
The product is suitable for users with intact skin whose anatomy (such as body dimensions and weight) permits the
intended use of the product.
The wheelchair may be used only with the options listed on the product order form.
Ottobock assumes no liability for combinations with medical devices and/or accessories for a medical device from
other manufacturers outside the modular system.
Combinations based on a combination agreement that have been evaluated for effectiveness and safety are an
exception to this.
3.2 Indications
•
Minor to pronounced or complete restrictions of mobility
3.3 Contraindications
3.3.1 Absolute Contraindications
•
None known
3.3.2 Relative Contraindications
•
Failure to meet physical or mental requirements
The product has a permanently welded frame. Therefore, the product is not suitable for users who require changes
to settings due to rapidly changing clinical pictures.
3.4 Qualification
Installation and adjustment tasks may only be carried out by qualified personnel. Compliance with all manufacturer
specifications and all applicable legal provisions is required. Please contact the manufacturer’s service department
for further information (see inside or outside of rear cover for addresses).
4 Safety
4.1 Explanation of warning symbols
WARNING
Warning regarding possible serious risks of accident or injury.
CAUTION
Warning regarding possible risks of accident or injury.
NOTICE
Warning regarding possible technical damage.
4.2 Safety instructions for assembly and adjustments
WARNING
Making incorrect adjustments
Risk of falling, tipping over or malposition of the user due to incorrect settings
►
Settings may only be changed by qualified personnel unless otherwise prescribed.
►
Before testing setting changes with the user seated, all screw connections must be firmly tightened.
►
Check the product for safety and functionality after changing the settings.