Ottobock | 19
Stiffness chart (spring – functional ring)
Patient Weight
Foot Size
21cm 22cm 23cm
24cm
25cm
26cm
27cm
28cm 29cm 30cm
kg
lbs
slim
normal
slim
normal
slim
normal
slim
normal
slim
normal
slim
normal
slim
normal
slim
normal
slim
normal
slim
normal
48-55
104-121 1-1 – 1-1 – 1-1 – 1-1 1-1 1-1 1-1 1-1 1-1 –
– – – – – – –
56-65
122-143 2-2 – 2-2 – 2-2 – 2-2 2-2 2-2 2-2 2-2 2-2 2-2 2-2 – 2-2 – 2-2 – 2-2
66-75
144-165 2-3 – 2-3 – 2-3 – 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 – 2-3 – 2-3 – 2-3
76-87
166-192 3-4 – 3-4 – 3-4 – 3-4 3-4 3-4 3-4 3-4 3-4 3-4 3-4 – 3-4 – 3-4 – 3-4
88-100 193-220 3-5 – 3-5 – 3-5 – 3-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5 – 3-5 – 3-5 – 3-5
101-112 221-247 – – – – – – –
– 4-6 4-6 4-6 4-6 4-6 4-6 – 4-6 – 4-6** – 4-6**
113-125 248-275 – – – – – – –
– 4-7 4-7 4-7 4-7 4-7 4-7 – 4-7 – 4-7** – 4-7**
126-137 276-302 – – – – – – –
– 5-8 5-8 5-8 5-8 5-8* 5-8* – 5-8* – 5-8* – 5-8*
138-150 303-330 – – – – – – –
– 5-9 5-9 5-9 5-9 5-9 5-9 – 5-9 – 5-9 – 5-9
* When combining this configuration with the CLeg, please contact Ottobock Customer Service.
** When combining this configuration with the CLeg or CLeg compact, please contact Ottobock Customer
Service.
2.5 Safety instructions
Please inform your patients about these safety issues!
CAUTION
Mechanical damage to the product
Injuries due to changes in or loss of functionality
• Use caution when working with the product.
• If the product is damaged, check it for proper function and readiness for use.
• In case of changes in or loss of functionality, do not continue using the product (see “Signs
of changes in or loss of functionality during use” in this section).
• Take any necessary measures (e.g. repair, replacement, inspection by the manufacturer’s
customer service, etc.).
• Inform the patient.
NOTICE
Damage due to incorrect environmental conditions.
Prosthetic components must not be exposed to the following elements:
• corrosive elements (such as fresh water, salt water, and acids)
• abrasive substances (e. g. sand)
The footshell material is not UV- or water-resistant.
Do not grind the surface of this prosthetic foot, as this can lead to premature wear.
Using this medical product under such conditions will render all claims against Otto Bock
HealthCare null and void.
Содержание 1C61 Triton Vertical Shock
Страница 3: ...Ottobock 3 1C61 Triton Vertical Shock Prosthetic Foot D K L F B 2 3 A E H G D F B C...
Страница 4: ...4 Ottobock 1C61 Triton Vertical Shock Prosthetic Foot 4 5 6 2 1 3 4 5 6...
Страница 5: ...Ottobock 5 1C61 Triton Vertical Shock Prosthetic Foot 7 8...
Страница 6: ...6 Ottobock 1C61 Triton Vertical Shock Prosthetic Foot 9 10...
Страница 186: ...186 Ottobock Ottobock 2C100 Ottobock 2C100 2C100 4 1 2 21 25 25 5 26 28 30 29 30 35...
Страница 190: ...190 Ottobock 6 10 7 SuperSkin 4 5 15 Nm 710D1 Loctite 636K13 4 6 30 4 Ottobock 4X262 1 5 5 1 5 2 93 42 I I VII...
Страница 203: ...Ottobock 203 Otto Bock HealthCare I 4 3 4 6 2 6 2 6 1 2 2 6 2 Triton Vertical Shock 1C61 3 4 Triton Vertical Shock 1C61...
Страница 205: ...Ottobock 205 4 1 4 1 1 I I Ottobock 2C100 I 2C100 Ottobock 2C100 4 1 2 cm mm 21 25 25 5 mm 26 28 30 29 30 35...
Страница 210: ...210 Ottobock 5 2 CE 93 42 VII...
Страница 214: ...214 Ottobock Otto Bock HealthCare 4 3 4 6 2 6 2 6 1 2 A B C D E F G H 2 6 2 Triton 1C61 3 4 Triton 1C61...
Страница 216: ...216 Ottobock 4 1 4 1 1 Ottobock 2C100 2C100 Ottobock 2C100 4 1 2 TT 21 25 25 5 26 28 30 29 30 35...
Страница 221: ...Ottobock 221 5 2 93 42 IX I VII...
Страница 230: ...230 Ottobock 4 5 15Nm 710D1 4 6 30 4 4X262 1 O 2 O 5 5 1 5 2 CE 93 42 EEC VII...
Страница 235: ...Ottobock 235 3 4 4 4 1 4 1 1 2C100 2C100 2C100 4 1 2 TT cm mm 21 25 25 5 mm 26 28 30 29 30 35...
Страница 247: ...Ottobock 247 710D1 636K13 Loctite 4 6 30 4 Ottobock 4X262 1 O O O 5 5 1 5 2 CE 93 42 EEC IX I VII...