background image

15

 

5.   FOLLOW PROCEDURE INSTRUCTIONS EXACTLY!  Do not take short cuts.  Follow the steps in 

 

       the order given.  Make certain to correctly time the waiting period for proper reaction and 

 

       color development.

 

6.   NEVER USE YOUR MOUTH TO DRAW REAGENTS INTO PIPETTES.  Always use the safety bulb 

 

      provided for the purpose.  In any tests involving hot flasks, beakers, or labware, use heat 

 

      resistant gloves or lab tongs.

 

 

7.   Dropping pipets are not fitted with bottle caps are not intended to be left in reagent 

 

      containers.  After use, they and regular pipets, tubes and other glassware should be washed 

 

      with water, rinsed with distilled or deionized water, and allowed to drain dry.  Be careful not 

 

      to place pipets on soiled work surfaces, where they could become accidently soiled and 

 

      contaminate a reagent bottle when reintroduced to it.

 

 

8.   When Handling potentially hazardous reagents, wear eye protection, protective clothing and 

 

      suitable gloves.  Where so cautioned in a procedure, strictly follow “use in well ventilated 

 

      areas” instructions if a suitable fume hood is not available.  It is wise to always work carefully 

 

      and neatly.  Be careful not to splash, spill, or drip reagents on skin, clothing, shoes, work 

 

      surfaces, etc.  If hazardous chemicals have accidently contacted skin or eyes, copiously flush 

 

      with water for 15 minutes, and if necessary call a physician.  Clean up and properly dispose of 

 

      spills immediately.  Wash hands thoroughly after use.

 

 

9.  Do not store reagents near food or use near where food is eaten.  Do not smoke near open 

 

      reagent bottles, especially irritants.  Replace and tighten reagent container bottle caps  

 

 

      immediately after use, and take special care not to interchange bottle caps.

4.3   Explanation of Safety Codes

For your safety and convenience, any hazardous reagent in a “Quick ‘n’ Easy” Test Kit has been specially 

coded.  WHEN THEY ARE APPLICABLE, Safety Code letters and numbers are listed after the name of such 

reagents at the beginning of the test procedures, and are explained on the following pages.  (If no Safety 

Code is listed, the reagent is not considered hazardous.  Nevertheless, ALL reagents should be kept out of 

the reach of those not authorized or trained to use them).

 

The first part of the code (LETTERS FROM “A” ONWARDS) refers to specific FIRST AID instructions 

 

detailed either directly on the label of each specific reagent bottle, or as explained below.

 

The second part of the code (NUMBERS FROM “1” UPWARDS) refers to specific DISPOSAL  

 

 

suggestions detailed below.

IMPORTANT:  To be prepared to deal with First Aid or disposal emergencies, check the codes, if any, listed 

in Section 6 for the Specific Test  Procedure.  Have immediate access to any items listed for first aid and/or 

disposal.

Содержание 942-095

Страница 1: ...Series 942 The Mini Analyst Instruction Manual 942 095 Hardness Total Low Range...

Страница 2: ...sing the required reagents by reading the MSDS Material Safety Data Sheets Failure could result in serious injury to the operator or damage to the instrument MSDS www orbeco com CAUTION The accuracy o...

Страница 3: ...General Operating Instructions 10 4 0 Important Reagent Safety and Disposal Precautions 13 4 1 Reagent Handling and Disposal 13 4 2 In Case of Emergency 13 4 3 Explanation of Safety Codes 14 4 4 First...

Страница 4: ...ut 2 line 16 character alphanumeric LCD Zero Set Automatic by microprocessor Standardization Set Automatic by microprocessor Housing Rugged corrosion and water resistant ABS plastic Faceplate Keypad S...

Страница 5: ...d expenses The test procedures in Section 7 are given in step by step easy to follow form with special instructions for your safety and convenience No user adjustments are ever needed LED Narrow Band...

Страница 6: ...er Always replace all 3 batteries at the same time and do not use a mixture of different brands Automatic Power off To conserve battery life the Model 942 shuts itself off automatically 15 minutes aft...

Страница 7: ...event finger marks on the sides of the tubes The containers used to obtain samples and labware used with the instrument should be clean both inside and out To avoid inaccurate results always wash and...

Страница 8: ...this requirement and can be inserted without any special orientation Reagent Tablets Instructions are given whether the tablet is simply allowed to dissolve or if it should be crushed with the crusher...

Страница 9: ...ly the result by the dilution factor 3 For an approximate ranging test measure 5mL or smaller volume into a sample tube and dilute to the 10mL line with distilled or deionized water Perform the test a...

Страница 10: ...afety Data Sheets are provided for all hazardous items Request copies of any you require Protect Model 942 From Temperature Extremes Humidity and Corrosive Gases Do not leave the unit in a vehicle boa...

Страница 11: ...Analyst instruments The sequence of steps covers how to activate the instrument and how to go through its automatic steps to guide you in completing each test After you press the On Off switch the in...

Страница 12: ...ns and Instructions A If display prompts DILUTE RETEST REMOVE SAMPLE Sample is beyond normal range see paragraph 2 3 of section 2 to dilute and then retest again starting with Step 2 above B If displa...

Страница 13: ...instrument will prompt INSERT SAMPLE TUBE meaning the NEXT Sample Tube Insert your next Sample Tube The instrument will now allow you to insert as many Sample Tubes as you wish without having to first...

Страница 14: ...nd or the corresponding Safety Codes comments given below 1 While most of our 68 Mini Analysts use safe reagent tablets it is unavoidable that a few tests use reagents that can be potentially hazardou...

Страница 15: ...skin or eyes copiously flush with water for 15 minutes and if necessary call a physician Clean up and properly dispose of spills immediately Wash hands thoroughly after use 9 Do not store reagents nea...

Страница 16: ...plenty of milk or water immediately Induce vomiting If unconscious or convulsing seek immediate medical attention INHALED Remove exposed person to fresh air at once If difficulty breathing occurs sta...

Страница 17: ...pills should be flushed with plenty of water mopped up and neutralized with 6 Molar Hydrochloric Acid before flushing down the drain with plenty of water Code 3 Chloroform Do NOT flush down drain Stor...

Страница 18: ...everal tests by inserting the blank and continuing as before BATTERIES LOW will continue to appear at the end of each subsequent test until either fresh batteries are installed or the batteries contin...

Страница 19: ...mark Are they positioned all the way down in the tube well D Is the reagent fresh or still valid If questionable retest with fresh reagent E Reviewed any notes in the directions about possible interf...

Страница 20: ...ccident or defects resulting from repairs alterations or installation made by any person or company not authorized by the manufacturer The manufacturer assumes no liability for consequential damage of...

Страница 21: ...er R 3684 If sample is turbid use an analytical quantitative filter paper to filter Samples can be stored if adjusted to pH 2 or less with Nitric Acid Pre Treatment of Sample Tubes This test will dete...

Страница 22: ...t necessarily indicate that hardness is present in this form Notes Note 1 If display reads Dilute and Retest dilute a fresh sample with distilled or deionized water retest and multiply reading by the...

Страница 23: ...23...

Страница 24: ...e Printed in USA 08 08 Rev 1 Orbeco Hellige is a registered trademark of Orbeco Hellige Inc Orbeco Hellige Inc 6456 Parkland Drive Sarasota Fl 34243 Phone 941 756 6410 800 922 5242 Fax 941 727 9654 se...

Отзывы: