4.0   Important Reagent Safety and Disposal Precautions

You are about to use an instrument which can be extremely helpful to you.  In our modern world, every 

mature person understands that many valuable devices are potentially dangerous if misused, or if they fall 

into the hands of those not qualified to use them properly.  For your safety, we call your attention to the 

possible dangers of misuse of testing reagents.  But at the same time we want to assure you that with 

intelligent use, our products can be powerful tools that can bring you great benefits and convenience.  

Follow the instructions carefully and intelligently, protect the equipment from harm, and it will give you 

long and excellent service.

4.1   Reagent Handling and Disposal Precautions

The “Quick ‘n’ Easy” reagent test kit supplied for use with each specific Model 942 has been designed to 

provide maximum convenience with accuracy and long term dependability.  To maintain this top 

performance and to avoid potential problems or accidents, it is in your personal interest to pay careful 

attention to the following safety precautions.

4.2   In Case Of Emergency

(If your specific test kit procedure lists a reagent with a safety code), read the corresponding explanations 

below.  If necessary, immediately call a physician or your local Poison Control Center (ask you telephone 

operator for assistance).  If you cannot get local help, in the continental USA call the The Poison Help hotline 

1-800-222-1222 (available 24 hours a day, 7 days per week).  Be prepared to explain what happened and to 

read the reagent’s label text and/or the corresponding Safety Codes comments given below.

 

1.   While most of our 68 Mini Analysts use safe reagent tablets, it is unavoidable that a few tests 

 

      use reagents that can be potentially hazardous.  It is your responsibility to understand all 

 

      safety requirements, maintain good safety practices, and take all steps to avoid harm.

 

 

2.   For your safety and convenience, we have identified and listed by codes any applicable safety 

 

      information for each such reagent.  These codes appear after each reagent where it is listed as 

 

      part of the “Quick ‘n’ Easy” test kit described at the beginning of the specific test procedure.  

 

      The information includes cautions on reagent handling and disposal, and antidotes in case of 

                              accidents.  Familiarize yourself thoroughly with this information before starting the test.   

 

 

      Always have immediate access to any specific items listed to cope with accidental spills.  In 

 

      addition, Material Safety Data Sheets are available for all applicable items at no charge.

 

 

3.   KEEP ALL REAGENTS LOCKED AND OUT OF THE REACH OF CHILDREN and others not  

  

  

       authorized for their use.  Many of our test kits utilize reagents in the form of convenient,  

 

 

       pre-measured tablets.  For storage, they are hermetically sealed in metal foil.  

These tablets  

 

       are not intended to be taken orally!

  Tear the foil open and drop the tablet into the Sample 

 

      Tube as directed in the test procedure, avoiding any contact with your fingers.

 
 

4. 

  

Always carefully read all text matter on reagent labels before opening the packages or  

 

                             bottles, and read the entire test procedure before starting.  If you are not certain what they 

 

      mean or what to do, always ask a qualified person for clarification or contact the   

 

 

      Orbeco-Hellige Service department at 941.756.6410 or by E-mail at [email protected]  

 

      before proceeding.

 

Содержание 942-095

Страница 1: ...Series 942 The Mini Analyst Instruction Manual 942 095 Hardness Total Low Range...

Страница 2: ...sing the required reagents by reading the MSDS Material Safety Data Sheets Failure could result in serious injury to the operator or damage to the instrument MSDS www orbeco com CAUTION The accuracy o...

Страница 3: ...General Operating Instructions 10 4 0 Important Reagent Safety and Disposal Precautions 13 4 1 Reagent Handling and Disposal 13 4 2 In Case of Emergency 13 4 3 Explanation of Safety Codes 14 4 4 First...

Страница 4: ...ut 2 line 16 character alphanumeric LCD Zero Set Automatic by microprocessor Standardization Set Automatic by microprocessor Housing Rugged corrosion and water resistant ABS plastic Faceplate Keypad S...

Страница 5: ...d expenses The test procedures in Section 7 are given in step by step easy to follow form with special instructions for your safety and convenience No user adjustments are ever needed LED Narrow Band...

Страница 6: ...er Always replace all 3 batteries at the same time and do not use a mixture of different brands Automatic Power off To conserve battery life the Model 942 shuts itself off automatically 15 minutes aft...

Страница 7: ...event finger marks on the sides of the tubes The containers used to obtain samples and labware used with the instrument should be clean both inside and out To avoid inaccurate results always wash and...

Страница 8: ...this requirement and can be inserted without any special orientation Reagent Tablets Instructions are given whether the tablet is simply allowed to dissolve or if it should be crushed with the crusher...

Страница 9: ...ly the result by the dilution factor 3 For an approximate ranging test measure 5mL or smaller volume into a sample tube and dilute to the 10mL line with distilled or deionized water Perform the test a...

Страница 10: ...afety Data Sheets are provided for all hazardous items Request copies of any you require Protect Model 942 From Temperature Extremes Humidity and Corrosive Gases Do not leave the unit in a vehicle boa...

Страница 11: ...Analyst instruments The sequence of steps covers how to activate the instrument and how to go through its automatic steps to guide you in completing each test After you press the On Off switch the in...

Страница 12: ...ns and Instructions A If display prompts DILUTE RETEST REMOVE SAMPLE Sample is beyond normal range see paragraph 2 3 of section 2 to dilute and then retest again starting with Step 2 above B If displa...

Страница 13: ...instrument will prompt INSERT SAMPLE TUBE meaning the NEXT Sample Tube Insert your next Sample Tube The instrument will now allow you to insert as many Sample Tubes as you wish without having to first...

Страница 14: ...nd or the corresponding Safety Codes comments given below 1 While most of our 68 Mini Analysts use safe reagent tablets it is unavoidable that a few tests use reagents that can be potentially hazardou...

Страница 15: ...skin or eyes copiously flush with water for 15 minutes and if necessary call a physician Clean up and properly dispose of spills immediately Wash hands thoroughly after use 9 Do not store reagents nea...

Страница 16: ...plenty of milk or water immediately Induce vomiting If unconscious or convulsing seek immediate medical attention INHALED Remove exposed person to fresh air at once If difficulty breathing occurs sta...

Страница 17: ...pills should be flushed with plenty of water mopped up and neutralized with 6 Molar Hydrochloric Acid before flushing down the drain with plenty of water Code 3 Chloroform Do NOT flush down drain Stor...

Страница 18: ...everal tests by inserting the blank and continuing as before BATTERIES LOW will continue to appear at the end of each subsequent test until either fresh batteries are installed or the batteries contin...

Страница 19: ...mark Are they positioned all the way down in the tube well D Is the reagent fresh or still valid If questionable retest with fresh reagent E Reviewed any notes in the directions about possible interf...

Страница 20: ...ccident or defects resulting from repairs alterations or installation made by any person or company not authorized by the manufacturer The manufacturer assumes no liability for consequential damage of...

Страница 21: ...er R 3684 If sample is turbid use an analytical quantitative filter paper to filter Samples can be stored if adjusted to pH 2 or less with Nitric Acid Pre Treatment of Sample Tubes This test will dete...

Страница 22: ...t necessarily indicate that hardness is present in this form Notes Note 1 If display reads Dilute and Retest dilute a fresh sample with distilled or deionized water retest and multiply reading by the...

Страница 23: ...23...

Страница 24: ...e Printed in USA 08 08 Rev 1 Orbeco Hellige is a registered trademark of Orbeco Hellige Inc Orbeco Hellige Inc 6456 Parkland Drive Sarasota Fl 34243 Phone 941 756 6410 800 922 5242 Fax 941 727 9654 se...

Отзывы: