Section 8 System Maintenance
Though the PV100
®
card systems are designed for years of trouble-free use, please perform the following
routine maintenance as indicated below to maximize the system’s service life.
Cabinet and Door
: Wipe down terminals with warm water, a mild detergent (dish soap) and a non-abrasive
cloth as needed. DO NOT power-wash or use a garden hose to rinse off the system! Standard automobile
wax may be used to protect the finish of the terminal’s cabinet and pedestal.
Display
: Do not use harsh detergents or any type of petroleum-based cleanser on the display.
l
Recommended Cleansers: AR Kleener, Diamond Glaze Anti-Reflective Cleaner.
Keypad
: Wipe down terminals with warm water, a mild detergent (dish soap) and a non-abrasive cloth as
needed. If Keypad becomes damaged, replace.
Door Locks
: Lubricate door locks every six (6) months or as needed. Use graphite or molybdenum disulfide
(“Moly-B”) dry lubricant. DO NOT apply too much lubricant.
Card Readers
:
l
Magnetic Card (All Terminals)
: Magnetic Card Readers contain magnetic heads like those on a
tape recorder. Depending on usage and environment (dusty), clean heads daily or every other day to
reduce the number of bad reads. Magnetic heads require periodic replacement.
l
Proximity
: Proximity readers are intended to be maintenance-free. A proximity reader that will not
recognize a compatible card should always be tested, first with multiple cards and then replaced if
necessary.
Heaters
: Units equipped with heaters should be checked for correct operation at the start of each cold
season.
NOTE:
The heater turns on at a temperature of 50°F (10°C). The heater turns off at 70°F
(21°C).
Doc. No.: M1900 Rev.: 8
Page 55 of 65
Содержание M1900
Страница 48: ...Program a Carded System Doc No M1900 Rev 8 Page 48 of 65...
Страница 56: ...Appendix A PV100 Primary Board PV100 Primary Board Doc No M1900 Rev 8 Page 56 of 65...
Страница 65: ......