Rotation of the QC and the tool - whether the QC connector
points to A,B,C,D side of the Angle Bracket when mounted
Internal mounting (QC
and tool are mounted
inward)
robot arm
Calculated (see
below)
Not
calculated
but
possible to
use
Not calculated
but possible to
use
Not
possible to
use
External mounting with QC connector on the A side
Coordinate system TCP [mm]
Center of Gravity [mm] Weight
X=0
Y= - 55 - (Tool Z value)
Z=63 + (Tool Y value)
RX=90°
RY=0°
RZ=0°
cX=0
cY= - 55 - (Tool Z value)
cZ= 63 + (Tool Y value)
0.207 kg
0.456 lb
Example with an RG2 tool:
TCP [mm]
Center of Gravity [mm]
X=0
Y= - 55 - 200 = - 255
Z= 63 + 0 = 63
RX=90°
RY=0°
RZ=0°
cX=0
cY= - 55 - 64 = - 119
cZ= 63 + 0 = 63
HARDWARE SPECIFICATION