NOTE:
During the fingertip design, the following shall be considered to maintain
optimal performance:
Clear optical path for the proximity sensors
Protect the proximity sensors from direct sunlight or strong light source
Avoid dust and liquid penetration
WARNING:
The proximity sensors are sensitive parts and shall be protected against:
Direct strong light (such as directional laser sources)
Direct high temperature
Mechanical contacts in any case
Expose to any liquid or fine conductive dust
NOTE:
Please clean regularly the proximity sensor surface with low pressure
compressed air (<5 bar) from a 5 cm distance. For stronger contamination use
isopropyl alcohol with a soft cotton swab to keep it clean.
Finger Thickness
The default fingertips are considered while the finger thickness has been set and could not
be changed in the software. In case when custom fingertips are used, the user should
manually compensate for the difference in the finger thickness.
8.1.2. Compute Box
8.1.2.1. With 1.5A Wall Adapter (36W)
Supplied Wall Adapter
Minimum
Typical
Maximum
Unit
Input voltage (AC)
100
-
240
[V]
Input current
-
-
1
[A]
Output voltage
-
24
-
[V]
Output current
-
1.5
-
[A]
Compute Box Power input (24V connector)
Minimum
Typical Maximum
Unit
Supply voltage
-
24
25
[V]
Supply current
-
1.5
-
[A]
HARDWARE SPECIFICATION
69
Содержание RG2-FT
Страница 1: ...USER MANUAL FOR UR ROBOTS v1 4 1 Original Instructions ...
Страница 61: ...On the Users tab click on the Add new user button to add more users ADDITIONAL SOFTWARE OPTIONS 61 ...
Страница 66: ...Proximity Sensor Typical Accuracy HARDWARE SPECIFICATION 66 ...
Страница 68: ...Dimensions of the Gripper s finger in millimeters HARDWARE SPECIFICATION 68 ...
Страница 74: ...8 2 4 Tools 8 2 4 1 RG2 FT All dimensions are in mm and inches HARDWARE SPECIFICATION 74 ...
Страница 82: ...12 Certifications CERTIFICATIONS 82 ...
Страница 83: ...12 1 EMC CERTIFICATIONS 83 ...
Страница 84: ...12 2 Declaration of Incorporation 12 2 1 RG2 FT CERTIFICATIONS 84 ...