6. Operation
NOTE:
It is assumed that the Installation has finished successfully. If not, first do the
installation steps in the previous section.
6.1. URCap Commands
URCap commands provide an easy way to program an application.
6.1.1. RG2-FT
NOTE:
At program start the force/torque finger sensors are automatically zeroed so
no need to place a HEX-Zero command at the beginning of the program.
Please make sure that the fingers are not in contact with any obstacle when
the program is started. Otherwise the sensors will not be properly zeroed.
6.1.1.1. RG Grip
When the
RG Grip
command is executed, the gripper will try to reach the specified target (W
(Width) and F (Force)) and, if selected, Depth compensation ON and/or Automatic centering
ON. The different functions are explained below.
NOTE:
To cancel any force/torque offset, execute an
HEX-Zero
command at the
beginning of the
RG Grip
command and make sure the gripper is not in
contact with any object before starting the program, otherwise the command
may not work properly.
OPERATION
28
Содержание RG2-FT
Страница 1: ...USER MANUAL FOR UR ROBOTS v1 4 1 Original Instructions ...
Страница 61: ...On the Users tab click on the Add new user button to add more users ADDITIONAL SOFTWARE OPTIONS 61 ...
Страница 66: ...Proximity Sensor Typical Accuracy HARDWARE SPECIFICATION 66 ...
Страница 68: ...Dimensions of the Gripper s finger in millimeters HARDWARE SPECIFICATION 68 ...
Страница 74: ...8 2 4 Tools 8 2 4 1 RG2 FT All dimensions are in mm and inches HARDWARE SPECIFICATION 74 ...
Страница 82: ...12 Certifications CERTIFICATIONS 82 ...
Страница 83: ...12 1 EMC CERTIFICATIONS 83 ...
Страница 84: ...12 2 Declaration of Incorporation 12 2 1 RG2 FT CERTIFICATIONS 84 ...