
Offset value: shows the value that, after calibration, will compensate the Raw value to have
usable Calibrated value.
Calibration
To calibrate the proximity sensor, follow the steps below.
1. Prepare a white paper and tap on Set proximity offset.
2. The gripper is opened (if it was closed) and a popup window will be shown.
3. Place the white paper between the fingers and tap on Continue.
4. The gripper will close and make a measurement to set the right offset. Wait until the
gripper is closed.
5. Once the gripper is opened the measurement is ready.
6. Tap on Yes to save the new offset and the setup is finished. To clear any offset previously
been set tap on No. To prevent any changes of the proximity offsets, tap on Cancel and
confirm it by taping on that again.
TCP
In the normal view of the panel the TCP of the robot can be overwritten by the TCP of the tool
by pressing the Automatic overwrite of the robot TCP configuration checkbox.
To see more options press on
and the following screen will show:
SW INSTALLATION
26
Содержание RG2-FT
Страница 1: ...USER MANUAL FOR UR ROBOTS v1 4 1 Original Instructions ...
Страница 61: ...On the Users tab click on the Add new user button to add more users ADDITIONAL SOFTWARE OPTIONS 61 ...
Страница 66: ...Proximity Sensor Typical Accuracy HARDWARE SPECIFICATION 66 ...
Страница 68: ...Dimensions of the Gripper s finger in millimeters HARDWARE SPECIFICATION 68 ...
Страница 74: ...8 2 4 Tools 8 2 4 1 RG2 FT All dimensions are in mm and inches HARDWARE SPECIFICATION 74 ...
Страница 82: ...12 Certifications CERTIFICATIONS 82 ...
Страница 83: ...12 1 EMC CERTIFICATIONS 83 ...
Страница 84: ...12 2 Declaration of Incorporation 12 2 1 RG2 FT CERTIFICATIONS 84 ...