3-6
Section 3
Setting Value Obtaining and Changing Command
ZS Series
CompoWay/F Communication Command Reference
Section 3
Unit No.
and P
a
rameter No.
Unit No.
Data No.
Parameter
Setting range/
output range
Remarks
08h 00h
Emitted light
amount
setting (Area 2)
0: Auto
1: Auto range
2: Fixed
(Note 1)
08h 02h
Light amount
control target
area
0: Peak
1: Surface
2: 2 areas
3: 3 areas
08h 06h
Emitted light
amount fixed
level
0 to 1000 (X0.1%)
Parameters when [Emitted light
amount setting]=[Fixed]
08h 0Dh
Emitted light
amount lowe
limit
0 to 800 (X0.1%
)
08h 0Eh
Emitted light
amount
upper limit
0 to 800 (X0.1%
)
Parameters when [Emitted light
amount setting]=[Auto range]
08h 11h
Measurement
target area
0: Surface
1: 2 areas
2: 3 areas
08h 25h
Received light
amount (surface)
0 to 4095 (tone)
08h 26h
Received light
amount (2 areas)
0 to 4095 (tone)
08h 27h
Received light
amount (3 areas)
0 to 4095 (tone)
Note 1: When no 2-area measurement is performed, Unit No. 2 is valid and Unit No. 7 and 8 are invalid.
When a 2-area measurement is performed, Unit No. 2 is invalid and Unit No. 7 and 8 are valid.
Example 1: When reading the setting values of edge threshold (when LDC is 1CH):
Since the edge threshold for Unit No. is 03h, and Data No. is 06h, values are shown as below:
02h 01h (C000h + 06h (Data No.)) 03h (Unit No.) 01h (CH No.) (8000h + 1h (Number of elements))
In the command section, the value is shown as below:
02h 01h C006h 0301h 8001h
To this command, if the response is shown as below:
02h 01h C006h 0301h 8001h 00000004h,
It indicates 50 % because the value is 4.