3
2-3
Section 2
Connections and settings of external devices
ZS Series
CompoWay/F Communication Command Reference
Section 2
Det
ails of Commands
Reading Parameter Areas
Read parameter areas.
List of Parameter Area Reading Commands
Data Name
MRC
SRC
Parameter
Type
Reading start
address
Specification
of element
numbers
Data to be read
Data
Length
*2
Bank switching
02h
01h
8000h
<Machine No.>
8001h
0 to 3
4
Keylock
02h
01h
A002h
<Machine No.>
8001h
0 : OFF, 1 : ON
4
Version
Information
02h
01h
A021h
<Machine No.>
8001h
Software Version
4
Controller type
Information
02h
01h
A022h
<Machine No.>
8001h
0 : ZS-LDC, 1 :
ZS-MDC
4
RS-232C Data
Length Setting
02h 01h A030h
<Machine
No.> 8001h
0
: 7 bits, 1 : 8 bits
4
RS-232C Parity
Setting
02h
01h
A031h
<Machine No.>
8001h
0 : None, 1 : Odd
Number,
2 : Even Number
4
Stop bits setting
02h
01h
A032h
<Machine No.>
8001h
0 : 1 bit, 1 : 2 bits
4
Communication
node setting
02h
01h
A033h
<Machine No.>
8001h
0 to 64
4
Digits after
decimal point
02h 01h A040
<Machine
No.> 8001h
0
: 1 digit, 1 : 2 digits,
2 : 3 digits,
3 : 4 digits, 4 : 5 digits
4
Digital "Eco"
mode
02h
01h
A041h
<Machine No.>
8001h
0 : NORMAL, 1 : ECO1,
2 : OFF
4
LCD ON/OFF
02h
01h
A042h
<Machine No.>
8001h
0 : OFF, 1 : AUTOOFF,
2 : ON
4
LCD Backlight
02h
01h
A043h
<Machine No.>
8001h
0 : OFF, 1 : AUTOOFF,
2 : ON
4
Sensor Load
02h
01h
A050h
<Machine No.>
8001h
0 : LOAD every time, 1 :
SAVE
4
Language
02h
01h
A051h
<Machine No.>
8001h
0 : Japanese, 1 :
English
4
Reading
processing unit
data *1
02h 01h C000h
+
<Data
No.>
XXYYh
XX : Unit No.
YY : Machine No.
8000h
+ <No. of
Elements>
Data to be read
8
*
1 - All reading/writing operations on processing units are assigned by using this command.
*
2 - Indicates ASCII character length. Refer to page 2-2 for details.
Refer to "Section 3 - Unit No. and Parameter No." for Unit No. and Parameter No.
for each processing unit.
Reading Parameter Areas