2-6
Section 2
About General Information of Communication Commands
ZS Series
CompoWay/F Communication Command Reference
Section 2
Det
ails of Commands
Writing Parameter Areas
Write parameter areas.
List of Parameter Area Writing Commands
Data Name
MRC
SRC
Parameter
Type
Writing start
address
Specification
of element
numbers
Data to be written
Data
Length
*2
Bank switching
02h
02h
8000h
<Machine No.>
8001h
0 to 3
4
KEYLOCK
02h
02h
A002h
<Machine No.>
8001h
0 : OFF, 1 : ON
4
RS-232C Data
Length Setting
02h
02h
A030h
<Machine No.>
8001h
0 : 7 bits, 1 : 8 bits
4
RS-232C Parity
Setting
02h
02h
A031h
<Machine No.>
8001h
0 : None, 1 : Odd Number,
2 : Even Number
4
Stop bits setting
02h
02h
A032h
<Machine No.>
8001h
0 : 1 bit, 1 : 2 bits
4
Communication
node setting
02h
02h
A033h
<Machine No.>
8001h
0 to 64
4
Digits after
decimal point
02h
02h
A040
<Machine No.>
8001h
0 : 1 digit, 1 : 2 digits, 2 : 3
digits, 3 : 4 digits, 4 : 5
digits
4
Digital "Eco" mode
02h
02h
A041h
<Machine No.>
8001h
0 : NORMAL, 1 : ECO1,
2 : OFF
4
LCD ON/OFF
02h
02h
A042h
<Machine No.>
8001h
0 : OFF, 1 : AUTOOFF,
2 : ON
4
LCD Backlight
02h
02h
A043h
<Machine No.>
8001h
0 : OFF, 1 : AUTOOFF,
2 : ON
4
Sensor Load
02h
02h
A050h
<Machine No.>
8001h
0 : LOAD, 1 : SAVE
4
Language
02h
02h
A051h
<Machine No.>
8001h
0 : Japanese, 1 : English
4
Writing processing
unit data *1
02h
02h
C000h
+
<Data No.>
XXYYh
XX : Unit No.
YY : Machine No.
8000h
+ <No. of
Elements>
Data to be written
8
*
1 - All reading/writing operations on processing units are assigned by using this command.
*
2 - Indicates ASCII character length. Refer to page 2-2 for details.
Refer to "Section 3 - Unit No. and Parameter No." for Unit No. and Parameter No. for
each processing unit.
Example 1: To turn on the "KEYLOCK" of the 2CH controller, assign a command as follows:
[Machine
No.]
=
0002h
、
[Data to be written]
=
0001h
MRC
SRC
Parameter Type
Reading start
address
Number of
elements
Data to be written
02h 02h A002h
0002h
8001h
0001h
Writing Parameter Areas