13
2-13
Section 2
Connections and settings of external devices
ZS Series
CompoWay/F Communication Command Reference
Section 2
Det
ails of Commands
Response
MRC SRC Response
Code
Instruction
Code
Related
Information 1
Related
Information 2
"30" "05"
2 bytes 2 bytes
4 bytes
2 bytes
2 bytes
4 bytes
Elements
Details
Response Code
Indicates controller status for the command.
Instruction Code
Related Information 1
Related Information 2
The code which is the same as the transmitted will be returned.
Response code for normal end
Response Code
Name
Details
"0000"
Normal end
No errors.
Response code when an error occurs
Response Code
Error Name
Cause
"1001"
Long command length
Command length is too long.
"1002"
Short command length
Command length is too short.
"1101"
Area type error
Instruction code is invalid.
"1103"
Start address outside of
range error
Related information specifies the sensor of the
unconnected Machine No.
"2203"
Operating error
Setting is abnormal.
Refer to the User's Manual of the ZS Series for error
conditions.
"2204"
Operating error
Operating mode of sensor is other than RUN.
"2205"
Operating error
Invalid command.