11
2-11
Section 2
Connections and settings of external devices
ZS Series
CompoWay/F Communication Command Reference
Section 2
Det
ails of Commands
Reading Controller Information
Read data about ZS Series types and so on.
Command
MRC SRC
"05" "01"
2 bytes 2 bytes
Response
MRC SRC Response
Code
Model Version
"05" "01"
2 bytes 2 bytes
4 bytes
20 bytes
20 bytes
Elements
Details
Response Code
Indicates controller status for the command. Data to be read is not
returned when an error occurs.
Model
Model is expressed with 20 ASCII characters.
Version
Version is expressed with 20 ASCII characters.
Response code for normal end
Response Code
Name
Details
"0000"
Normal end
No errors.
Response code when an error occurs
Response Code
Error Name
Cause
"1001"
Long command length
Command length is too long.
"1002"
Short command length
Command length is too short.
Reading Controller Information