36
Run-Mode Measurement Process
Individual Judgement
How to get Individual Judgement Output
1.
Parallel ‘DO 0 to 31’Signals
DO[0:15] signals’ (ON/OFF) indicates the Individual judgements
(OK or NG).
Setting about Individual Judgement
Able/Disable
MENU mode - [System] - [Output] - [Judgement output] - [Parallel]
If selecting ON, judgements are output.
ON (default) / OFF
MENU mode - [System] - [Comm] - [Parallel]
Output Polarity
(OR, DO[0:15])
ON condition of OR and Individual Judgement
NG=ON: Signals turn ON when judgement is NG. (default )
OK=ON: Signals turn ON when judgement is OK.
Output cycle
Output cycle time. Set the time that is “Gate ON delay + Gate ON time”or more
and that is shorter than the measurement cycle.
Range:
2.0 to 10000.0 ms (default: 10.0 ms)
Gate ON delay
Delay time from output of measurement result to DO[0:15] until GATE signal
turns on.
Range:
1.0 to 10000.0 ms (default: 1.0 ms)
Gate ON time
Range:
1.0 to 10000.0 ms (default: 5.0 ms)
Handshaking
Set the output method.
OFF:
Measurement results are output asynchronously
with external device. (default)
ON:
Measurement results are output synchronously with external device.
Timeout
In case of “Handshaking = ON”, a timeout error occurs when there is no
response from external device within timeout period.
Range:
1.0 to 60.0 s (default: 10 s)
DO15
Expression 15
DO14 DO13 DO12 DO11 DO10 DO9 DO8 DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0
DO15 DO14 DO13 DO12 DO11 DO10 DO9 DO8 DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0
Expression 0
Expression 31
Expression 16
Judgment result for expression 0 to 15
Judgment result for expression 16 to 31
1st time
2nd time
Z01E-EN-01+ZFX+SettingGuide.book Seite 36 Mittwoch, 13. Februar 2008 2:38 14