31
2-6 Changing the Display Information (ADJ/RUN Mode)
Main Operation
2-6
Changing the Display Information (ADJ/RUN Mode)
Measurement results and another information are displayed on LCDscreen. In
ADJ mode, saved images can be displayed. The currently saved measure-
ment data can also be checked using the logging monitor and statistical data
(only C20/25).To switch the screen display, either select [Display SW] or press
the F3 key.
Previous
Next
Dsplay SW
Capture
Individual result
Camera 0
0.Bank00
0.Pattern Search
Judge OK
Correlation 92
Position X 462
Position Y 352
Angle 15
TEA
Dsplay SW
Capture
All results/Region
TEA
Dsplay SW
Capture
All results/Judge
0
0
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
OK
353ms
OK
353ms
OK
353ms
Previous
Next
Dsplay SW
Capture
Data list(0-15)
Data0 *******.***
Data1 *******.***
Data2 *******.***
Data3 *******.***
Data4 *******.***
Data5 *******.***
Data6 *******.***
Data7 *******.***
Data8 *******.***
Data9 *******.***
Data10 *******.***
Data11 *******.***
Data12 *******.***
Data13 *******.***
Data14 *******.***
Data15 *******.***
Previous
Next
Dsplay sw
Capture
Position
TEA
Camera 0
0.Bank00
0.Pattern Search
Judge OK
Correlation 92
Position X 462
Position Y 352
Angle 15
X direction 20.111
Y direction 42.513
Angle 12.652
OK
353ms
Previous
Next
Dsplay SW
Capture
Variables list( 0-15)
Var.0 *******.***
Var.1 *******.***
Var.2 *******.***
Var.3 *******.***
Var.4 *******.***
Var.5 *******.***
Var.6 *******.***
Var.7 *******.***
Var.8 *******.***
Var.9 *******.***
Var.10 *******.***
Var.11 *******.***
Var.12 *******.***
Var.13 *******.***
Var.14 *******.***
Var.15 *******.***
OK
353ms
OK
353ms
TEA
Judge0 *******.***
Judge1 *******.***
Judge2 *******.***
Judge3 *******.***
Judge4 *******.***
Judge5 *******.***
Judge6 *******.***
Judge7 *******.***
Judge8 *******.***
Judge9 *******.***
Judge10 *******.***
Judge11 *******.***
Judge12 *******.***
Judge13 *******.***
Judge14 *******.***
Judge15 *******.***
Previous
Next
Dsplay SW
Capture
Judges list(0-15)
OK
353ms
Previous
Next
Dsplay SW
Stored image
OK
353ms
Log SW
Display SW
Capture
Logging monitor/Data0
Data 276.000
Time 15:10:00
250
300
350
Warning
50
100
150
200
Statistical data/Data0
Maximum 462
Minimum 370
Average 423
Deviation 210
Count 100
NG Count
5
NG Rate
5%
Alarm Cou
20
Log SW
Display SW
Capture
Individual results
All results/Region
All results/Judge
Results are displayed indi-
vidually for each measure-
ment item.
The entire measurement
region is displayed.
All measurement results are
displayed as a list.
Horizontal axis: Smallest digit of item No.
Vertical axis:
Upper two digits of item No.
Green circle:
OK
Red circle:
NG
Position correction
Variables list
Data list
The position correction
result is displayed.
The data results are
displayed as a list.
The variable results are
displayed as a list.
Judgement list
Stored image
Logging monitor
The judgement results are
displayed as a list.
Saved images are dis-
played.
Only ADJ-Mode
Conditions can be adjusted
while viewing the measure-
ment results saved to the
logging monitor.
Only ZFX-C20/25
Statistical data
The statistical data saved
to the logging monitor is
displayed.
Only ZFX-C20/25
Z01E-EN-01+ZFX+SettingGuide.book Seite 31 Mittwoch, 13. Februar 2008 2:38 14