SECTION 3
Run-Mode Measurement Process
There are two measurement-mode. In TRIG measurement-mode, TRIG is the
first event and one measurement is done. In continuous measurement-mode,
continuous measurement command is the first event and measurements are
done repeatedly until stop command.
TRIG
How to input
1.
Serial Command via RS-232C/422, USB, Ethernet
It’s needed to send the command from external device (e.g. PC, PLC)
Please see the detail in “Serial Communication Command Reference“
2.
Parallel (TRIG Signal)
One measurement is done if TRIG signal is turn ON.
Continuous Measurement Command and Stop Command
How to input
1.
Serial Command via RS-232C/422, USB, Ethernet
It’s needed to send the command from external device (e.g. PC, PLC)
Please see the detail in “Serial Communication Command Reference”
2.
Parallel Communication
• Continuous Measurement Command
It’s needed to send the command from external device (e.g. PLC)
Please see the detail in “User’s manual”
During continuous measurement, it’s needed to keep the state of input
command.
• Stop Command (Stop condition)
If the status of continuous measurement command breaks, continuous
measurement is ended.
TRIG Measurement-Mode
Continuous Measurement-Mode
TRIG
Measurement
Result output
Continuous Measurement Command
Measurement
Result output
Stop Command ?
End
Wait for next TRIG
Yes
No