Event name
Safety Process Data Communications Timeout
Event code
80300000 hex
Meaning
A communications timeout occurred in safety process data communications with the Safety Control Unit.
Source
Depends on where the Sysmac
Studio is connected and the sys-
tem configuration.
Source details
NX Unit
Detection tim-
ing
When estab-
lishing or dur-
ing safety proc-
ess data com-
munications
Error attrib-
utes
Level
Minor fault
Recovery
For request to
establish com-
munications
from Safety
CPU Unit after
removing
cause of error
Log category
System
Effects
User program
Continues.
Operation
The Unit continues to operate. The safe states are
used for the I/O data of the safety connection
where the error was detected.
System-de-
fined varia-
bles
Variable
Data type
Name
None
None
None
Cause and
correction
Assumed cause
Correction
Prevention
A setting is not correct. The set-
ting of the safety task period is
too short.
Increase the safety task period
and then transfer the settings to
the Safety CPU Unit.
Set the system configuration and
setup according to the correc-
tions that are given on the left.
There is excessive noise.
Implement noise countermeas-
ures.
Implement noise countermeas-
ures if excessive noise caused
the error.
The Safety CPU Unit or safety
slave entered a status where it
could not continue safety proc-
ess data communications.
Check the status of the Safety
CPU Unit or safety slave.
Refer to troubleshooting informa-
tion for the Safety CPU Unit or
safety slave.
An error or status change occur-
red in the NX Bus Master to
which the Unit is connected, pre-
venting correct process data
communications.
Check the status of the NX Bus
Master to which the Unit is con-
nected.
Set the system configuration and
setup according to the correc-
tions that are given on the left.
Attached in-
formation
None
Precautions/
Remarks
None
12 Troubleshooting
12 - 75
NX-series Safety Control Unit User's Manual (Z930)
12-3 Checking for Errors with the Sysmac Studio
12
12-3-4 Error Descriptions
Содержание NX-SIH400
Страница 4: ...Introduction 2 NX series Safety Control Unit User s Manual Z930 ...
Страница 46: ...Revision History 44 NX series Safety Control Unit User s Manual Z930 ...
Страница 108: ...2 Specifications 2 42 NX series Safety Control Unit User s Manual Z930 ...
Страница 132: ...3 Installation and Wiring 3 24 NX series Safety Control Unit User s Manual Z930 ...
Страница 148: ...4 Safety Control Unit Operation 4 16 NX series Safety Control Unit User s Manual Z930 ...
Страница 216: ...5 System Configuration and Setup 5 44 NX series Safety Control Unit User s Manual Z930 ...
Страница 306: ...6 Programming 6 90 NX series Safety Control Unit User s Manual Z930 ...
Страница 378: ...7 Checking Operation and Actual Operation 7 72 NX series Safety Control Unit User s Manual Z930 ...
Страница 390: ...8 Calculating Safety Reaction Times 8 12 NX series Safety Control Unit User s Manual Z930 ...
Страница 412: ...11 Safety Data Logging 11 10 NX series Safety Control Unit User s Manual Z930 ...
Страница 504: ...12 Troubleshooting 12 92 NX series Safety Control Unit User s Manual Z930 ...
Страница 550: ...l Safety I O Terminal Settings l I O Map Settings Appendices A 38 NX series Safety Control Unit User s Manual Z930 ...
Страница 554: ...l I O Map Settings Appendices A 42 NX series Safety Control Unit User s Manual Z930 ...
Страница 558: ...l Safety I O Terminal Settings l I O Map Settings Appendices A 46 NX series Safety Control Unit User s Manual Z930 ...
Страница 564: ...l Safety I O Terminal Settings l I O Map Settings Appendices A 52 NX series Safety Control Unit User s Manual Z930 ...
Страница 623: ...I Index I 1 NX series Safety Control Unit User s Manual Z930 I ...
Страница 625: ......